48
STAGEPAS 600i
3-10. A-MUTE inspection
Conduct level check when analog mute (SP OUT side).
Input measuring result on A-MUTE test.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value PASS
PASS: A-MUTE LEVEL
When Abnormal
Measurement value FAIL
FAIL: A-MUTE LEVEL
Troubleshooting
In FAIL, check IC504 (3, 6pin) on a DSP circuit board,
the parts of the circumference of it, and wiring to an
AMPS circuit board.
3-11. DA-MUTE inspection
Conduct level check when DA mute (SP OUT side).
Simultaneously, Conduct level check when DA mute
(MONITOR OUT side).
Input measuring result on DA-MUTE test.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
3-10. A-MUTE 検査
アナログミュート時(SP OUT 側)のレベル確認を
行います。
A-MUTE テストでの計測結果を入力します。
結果が PASS の場合、「Yes」ボタンをクリックし
ます。結果が FAIL の場合、「No」ボタンをクリッ
クします。
オペレータの計測結果に応じた結果判定を入力する
と、検査結果はアウトプットウインドウへ下記のよ
うに表示されます。
正常時
計測値 PASS
PASS:
A-MUTE LEVEL
異常時
計測値 FAIL
FAIL:
A-MUTE LEVEL
トラブルシューティング
FAIL の場合、DSP シート上の IC504(3,6pin) とそ
の周辺の部品および AMPS シートまでの配線を確
認してください。
3-11. DA-MUTE 検査
DA ミュート時(SP OUT 側)のレベル確認を行い
ます。
同時に、DA ミュート時(MONITOR OUT 側)の
レベル確認を行います。
DA-MUTE テストでの計測結果を入力します。
結果が PASS の場合、「Yes」ボタンをクリックし
ます。結果が FAIL の場合、「No」ボタンをクリッ
クします。
Содержание Stagepas 600i
Страница 27: ...27 STAGEPAS 600i Scale 90 100 AMPS Circuit Board Pattern side パターン側 2NA ZA38610 1 ...
Страница 29: ...29 STAGEPAS 600i 2NA WZ89830 Pattern side パターン側 MIX62 Circuit Board to DSP CN401 to DSP CN502 ...
Страница 32: ...STAGEPAS 600i 32 Pattern side パターン側 Component side 部品側 SUB61 Circuit Board to AMPS CN101 2NA ZA38150 3 ...