CAUTION!
Using this product with the protection function disabled may cause further damage to this unit. Use special care for this
point when using this mode.
●
Starting Self-Diagnostic Function in the protection cancel mode
If the protection function works and causes hindrance to trouble shoot, cancel the protection function as described below,
and it will be possible to enter the self-diagnostic function mode. (The protection functions other than the excess current
detect function will be disabled.)
While pressing the “TONE CONTROL” and “INFO” keys, press the “MAIN ZONE ” key to turn on the power and keep
pressing those 2 keys for 3 seconds or longer.
The self-diagnostic function mode is activated with the protection functions disabled.
In this mode, the “SLEEP” segment of the FL display flashes to indicate that the mode is self-diagnostic function mode with
the protection functions disabled.
●
Starting Self-Diagnostic Function
While pressing the “TONE CONTROL” and “INFO” keys, press the “MAIN ZONE ” key to turn on the power.
The self-diagnostic function mode is activated.
Keys of this unit
While pressing these keys, t
u
rn on the power.
30
RX-V671/HTR-6064/RX-A710
RX-V671/HTR-6064/
RX-A71
0
DRAFT