27
English
AUTO SETUP
PRE
P
ARA
T
ION
■
Troubleshooting for auto setup procedure
Before auto setup
During auto setup
Press –/+ to display the detailed information about the individual error. Select RETRY to try auto setup procedure again.
After auto setup
Press –/+ to display the detailed information about the individual error.
• If the warning message W-2 or W-3 appears on the OSD, no corrections are made. In such cases, correct the problem, select CHECK
in DISTANCE or LEVEL, then perform the auto setup procedure again.
• If the message W-1, W-4 or W-5 appears on the OSD, corrections are made. However, the corrections may not be correct. In such
cases, correct the problem, then perform the auto setup procedure again on the relevant setting items.
Error message
Cause
Remedy
Connect MIC!
Optimizer microphone is not connected.
• Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
Unplug HP!
Headphones are connected.
• Unplug the headphones.
Error message
Cause
Remedy
E-1:NO FRONT SP
Front L/R channel signal(s) is(are) not detected.
• Select the front speakers with SPEAKER A or B.
• Check the front L/R speaker connections.
E-2:NO SURR.SP
A surround channel signal is not detected.
• Check the surround speaker connections.
E-3:NO PRES. SP
A presence channel signal is not detected.
• Check the presence speaker connections.
E-4:SBR->SBL
Only right surround back channel signal is
detected.
• Connect the surround back speaker to the LEFT
SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.
E-5:NOISY
Background noise is too loud.
• Try auto setup procedure in quiet environment.
• Turn off noisy electric equipment like air conditioners
(etc.) or move it away from this unit.
E-6:CHECK SURR.
Surround back speaker(s) is(are) connected,
though surround L/R speakers are not.
• Connect surround speakers when you use (a)
surround back speaker(s).
E-7:NO MIC
The optimizer microphone was unplugged
during the auto setup procedure.
• Connect the supplied optimizer microphone to
OPTIMIZER MIC jack on the front panel.
E-8:NO SIGNAL
The optimizer microphone does not detect test
tones.
• Check the microphone setting.
• Check the speaker connections and placement.
E-9:USER CANCEL
The auto setup procedure was cancelled
because a setting which affects the auto setup
was changed during the procedure.
• Perform the auto setup procedure again.
Warning message
Cause
Remedy
W-1:OUT OF PHASE
Speaker polarity is not correct. This message
may appear depending on the speakers even
when the speakers are connected correctly.
• Check the speaker connections.
W-2:OVER 24m
(80ft)
The distance between the speaker and the
listening position is over 24 meters (80ft).
• Bring the speaker closer to the listening position.
W-3:LEVEL ERROR
The difference of volume level among speakers
is excessive. (No level correction is made.)
• Readjust the speaker installation.
• Check the speaker connections.
• Use speakers of similar quality.
• Adjust the output volume of the subwoofer.
W-4:SWFR PHASE
The phase polarity of the subwoofer is not
correct.
• We recommend that you select the opposite phase on
the subwoofer if the subwoofer has a phase switch.
W-5:VOL ERROR
The result may not be correct because the
volume was changed during the auto setup
procedure.
• Perform the auto setup procedure again. Do not
change the volume during the auto setup procedure.
00_RX-V2400U_EN.book Page 27 Friday, October 10, 2003 10:54 AM