38
MIDI Data Format
2.1.3.1 XG System On
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0001nnnn
1NH
N:device Number
01001100
4CH
Model ID
00000000
00H
Address High
00000000
00H
Address Mid
01111110
7EH
Address Low
00000000
00H
Data
11110111
F7H
End of Exclusive
When ON is received, the SOUND MODULE MODE changes to XG.
Since approximately 50ms is required to process this message, be sure to
allow an appropriate interval before sending the next message.
2.1.3.2 XG System parameter change
This message sets the XG SYSTEM block (see Tables <1-1> and <1-2>).
2.1.3.3 Multi Part parameter change
This message sets the Multi Part block (see Tables <1-1> and <1-3>).
2.1.4 PLG150-PF Native parameter change
This message sets parameters unique to the PLG150-PF.
Each message sets a single parameter. The message format is as follows.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0001nnnn
1NH
N:Device Number
01100111
67H
Model ID
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
11110111
F7H
End of Exclusive
For parameters whose Data Size is 2 or 4, the appropriate amount of data will
be transmitted as indicated by Size.
2.1.4.1 PLG150-PF System parameter change
This message sets the PLG150-PF SYSTEM block (see Tables <2-1> and
<2-2>).
2.1.4.2 PLG150-PF Part parameter change
This message sets the PLG150-PF MULTI PART block (see Tables <2-1>
and <2-3>).
2.2 Bulk dump
This device uses only the following bulk dump messages.
[ XG BULK DUMP ]
1) XG System bulk dump
2) Multi Part bulk dump
[ PLG150-PF NATIVE BULK DUMP ]
1) System bulk dump
2) Part bulk dump
2.2.1 XG bulk dump
This message sets XG-related parameters. Unlike parameter change mes-
sages, a single message can modify multiple parameters.
This message format is as follows.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
01001100
4CH
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
Address and Byte Count are given in tables <1-n>.
Byte Count is indicated by the total size of the Data in tables <1-n>.
Bulk dump is received when the beginning of the block is specified in
"Address."
"Block" indicates the unit of the data string that is indicated in tables <1-n>
as "Total Size."
Check sum is the value that produces a lower 7 bits of 0 when this Start
Address, Byte Count, Data, and the Check sum itself are added.
2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (see Tables <1-1> and <1-2>).
2.2.1.2 Multi Part bulk dump
This message sets the MULTI PART block (see Tables <1-1> and <1-3>).
2.2.2 PLG150-PF Native Bulk Dump
This message sets the special parameters for PLG150-PF.
Unlike Parameter change, one message can modify multiple parameters.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
01100111
67H
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
The detail are the same as for 2.2.1 XG Bulk Dump. However, see Tables <2-
n> for the Address, Byte, Count, and block.
2.2.2.1 PLG150-PF Native System bulk dump
This message sets the PLG150-PF SYSTEM block (see Tables <2-1> and
<2-2>).
2.2.2.2 PLG150-PF Native Part bulk dump
This message sets the PLG150-PF MULTI PART block (see Tables <2-1>
and <2-3>).
3. Realtime Messages
3.1 Active Sensing
a) Send
This is not transmitted.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400
msec, PLG150-PF will act the same as when ALL SOUND OFF, ALL
NOTE OFF, and RESET ALL CONTROLLERS are received,
and return to the condition where has not been received once.