36
MIDI Data Format
1.2.16 Data Increment/Decrement (for RPN)
This message is used to increment or decrement values for parameters specified
by RPN (see 1.2.18), in steps of 1.
Control#
Parameter
Data Range
96
RPN Increment
—
97
RPN Decrement
—
The data byte is ignored.
1.2.17 NRPN (Non-registered parameter number)
This is a message for setting the sound for things like vibrato, filter or EG. Use
NRPN MSB and NRPN LSB to specify the parameter that you wish to modify,
and then use Data Entry (see 1.2.4) to set the value for the specified parameter.
Control#
Parameter
Data Range
98
NRPN LSB
0...127
99
NPRN MSB
0...127
If the Multi Part parameter Rcv NRPN = OFF, that part will not receive NRPN.
The following NRPN messages can be received.
*1 See 1.2.4
*2 “--” means that the set value will be ignored.
*3 Adjusts the time after the note is played until vibrato begins to take effect. The
effect will begin more quickly for lower values, and more slowly for higher
values.
1.2.17 RPN (Registered parameter number)
This message is used to specify part parameters such as Pitch Bend Sensitivity or
Tuning. Use RPN MSB and RPN LSB to specify the parameter that you wish to
modify, and then use Data Entry (see 1.2.4) to set the value of the specified
parameter.
Control#
Parameter
Data Range
100
RPN LSB
0 ... 127
101
RPN MSB
0 ... 127
If the Multi Part parameter Rcv RPN = OFF, that part will not receive this mes-
sage.
The following RPN messages can be received.
*1 Refer to 1.2.4
*2 “--” means that the set value will be ignored.
1.2.19 Assignable controller
By assigning a control change number of 0...95 to a part, application of effects
can be controlled. This device allows two control change numbers (AC1 and
AC2) to be specified for each part.
The following parameters specify the effect of AC1 and AC2:
* Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH
The AC1 control change number is specified by the Multi Part parameter ACl
CONTROLLER NUMBER, and the AC2 control change number is specified by
the Multi Part parameter AC2 CONTROLLER NUMBER.
1.3 Channel mode messages
These messages specify the basic operation of a part.
1.3.1 All Sound Off
This message silences all notes being played on the corresponding channel.
However, channel messages such as Note-on and Hold-on will be maintained in
their present state.
Control#
Parameter
Data Range
120
All Sound Off
0
1.3.2 Reset All Controllers
This message changes the settings of the following controllers.
The following data is not changed
Parameter values specified for program change, bank select MSB/LSB, volume,
pan, effect send levels 1, 3, 4, RPN and NRPN.
Control#
Parameter
Data Range
121
Reset All Controllers
0
1.3.3 All Note Off
This message turns off all notes which are currently on for the corresponding
part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these
are turned off.
Control#
Parameter
Data Range
123
All Note Off
0
1.3.4 Omni Off
Works the same as when All Note Off is received.
Control#
Parameter
Data Range
124
Omni Off
0
1.3.5 Omni On
Works the same as when All Note Off is received.
Control#
Parameter
Data Range
125
Omni On
0
1.3.6 Mono
Works the same as when All Sound Off is received, and if the value (mono num-
ber) is in the range of 0... 16, sets the corresponding channel to Mode4* (m = 1).
Control#
Parameter
Data Range
126
Mono
0 ... 16
* Mode4 is a state in which only channel messages on the specified channel will
be received, and notes will be played individually (monophonically).
1.3.7 Poly
Works the same as when All Sound Off is received, and sets the corresponding
channel to Mode3*.
Control#
Parameter
Data Range
127
Poly
0
* Mode3 is when channel messages will be received only on the specified chan-
nel, and notes will be sounded polyphonically.
NRPN
MSB LSB
Data Entry*1
MSB LSB
Parameter Name and Data Range
01H 08H
mm -- *2
Vibrato rate
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 09H
mm --
Vibrato depth
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 0AH
mm -- *3
Vibrato delay
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 20H
mm --
Low pass filter cutoff frequency
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 21H
mm --
Low pass filter resonance
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 63H
mm --
EG Attack Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 64H
mm --
EG Decay Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
01H 66H
mm --
EG Release Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
RPN
MSB LSB
Data Entry*1
MSB LSB
Parameter name and value range
00 00H
mm --*2
Pitch bend sensitivity
mm: 00-18H (0...+24 semitones)
Specify up to 2 octaves in semitone steps
00 01H
mm ll
Fine tuning
mm ll: 00H 00H -100 cents
:
:
mm 11: 40H 00H 0 cents
:
:
mm ll: 7FH 7FH +100 cents
Note: The next after mm 11: 00H 7FH (= -87.5) cent
is 01H 00H (-87.4) cents.
00H 02H
mm --
Coarse tuning
mm: 28H - 40H - 58H (-24...0...+24 semitones)
7FH 7FH
-- --
RPN Null
This empties settings from RPN and NRPN numbers.
Internal data is not affected.
Controller
Value
Pitch bend change
Channel pressure
Polyphonic key pressure
Modulation
Expression
Hold
Portamento
Sostenuto
RPN
NRPN
±0 (Center)
0 (OFF)
0 (OFF)
0 (OFF)
127 (Max.)
0 (OFF)
0 (OFF)
0 (OFF)
Number unset, internal data is not affected.
Number unset, internal data is not affected.