II-52
●
DKV Pro
Error Messages
If an error message is displayed, refer to the following table for details on the correct action to table.
No.
Message
Message in History
Meaning
Coorective Action
[00]
“PIANO POWER OFF”
“(KEY THERMISTOR)”
KEY THERMISTOR
Key-drive temperature sensor was
tripped.
(Or sensor is broken or incorrectly
connected.)
Wait for temperature to drop before
resuming playback.
Check whether sensor is correctly
connected. (KMC board: CN108)
[01]
“PIANO POWER OFF”
“(PDL THERMISTOR)”
PDL THERMISTOR
Pedal temperature sensor was
tripped.
(Or sensor is broken or incorrectly
connected.)
Wait for temperature to drop before
starting or resuming playback.
Check whether sensor is correctly
connected. (PMC board: CN9,
CN10)
[02]
“PIANO POWER OFF”
“(KEY FET ERROR)”
KEY FET ERROR
Key-drive protection circuit was
tripped.
(Caused by FET failure or loss of
80V power.)
If broken FET on drive board
→
Replace the drive board.
If 80V-power loss
→
Replace fuse
or power unit.
[03]
“PIANO POWER OFF”
“(PDL CPU DOWN)”
PDL CPU DOWN
No communication between PMC
and KMC.
(Problem with PMC system)
Turn power off and then back on.
Check the PMC
←→
KMC con-
nection.
Replace the PMC board.
[04]
“KEY DATA TABLE”
“DISABLE”
KEY DATA TABLE
Key playback table is corrupted.
(Will also occur after board
replacement until initial measure-
ments are taken.)
Go to Maintenance Mode and exe-
cute the “All key data measure”
operation.
[05]
“PDL PARAMETER”
“DISABLE”
PDL PARAMETER
Pedal measurement data is cor-
rupted.
(Will also occur after board
replacement until initial measure-
ments are taken.)
Go to Maintenance Mode and exe-
cute the “Pedal stroke measure”
operation.
[06]
“SENSOR”
“DISABLE”
SENSOR DISABLE
One or more keys failed to gener-
ate a hammer-sensor event during
“Sensor measure” or “All key data
measure” operation. This error
occurs only during Maintenance
Mode.
Check the connection at the sen-
sor connector.
If this error message appears, the
piano will also play out the bad
keys, in order. Check the hammer
sensors for each of the keys that
are played (using the “Sensor unit
test”). Note that this error may also
occur if key’s drive system is bad
(if the drive system was unable to
drive the key.)
[07]
“SENSOR”
“NOT. CONNECTED!”
SNS NO CONNECT
No response from sensor at power
on.
Turn power off and back on.
Check connection at sensor con-
nector.
[08]
“LOUD PDL ERROR”
“OVERLOAD!”
LOUD OVERLOAD
Pedal’s cumulative current
exceeded the limit value. (Over-
load)
If pedal-stroke has changed from
measured stroke:
Check that sensor positions are
correct, and then carry out the
“Pedal stroke measure” operation.
If pedal is blocked by foreign mat-
ter
→
Remove the obstruction.
[09]
“SHIFT PDL ERROR”
“OVERLOAD!”
SHIFT OVERLOAD
Содержание MX-1
Страница 1: ...HYBRID PIANO PRODUCT HANDBOOK FOR THE PIANO TECHNICIAN MHB19 00 08 CR Printed in Japan ...
Страница 6: ......
Страница 7: ...I 1 Part I Product Description ...
Страница 8: ...I 0 ...
Страница 50: ...I 42 ...
Страница 51: ...II 1 Part II Servicing ...
Страница 52: ...II 0 ...
Страница 68: ...II 16 Grand models The following label is attached to the inside cover of the pedal drive unit MarkII ...
Страница 105: ...II 53 ...
Страница 116: ......