manualshive.com logo in svg
background image

 

3

ME02R96

ENGLISH

 

 

Note About Versions and Upgrades

 

System software:

 

The ME02R96 includes system version 1.20 or higher, and is not compatible with pre-V1.20 soft-
ware. Before upgrading your 02R96 again in the future, be sure that your updater program is V1.20
or higher.

 

Studio Manager: 

 

The ME02R96 is not compatible with Studio Manager versions prior to V1.1.1. If your version is
older than V1.1.1, please replace it by installing the Studio Manager version included on the accom-
panying CD-ROM. For information about how to carry out the installation, refer to Studio Manager’s
installation guide.

Note that Macintosh system requirements are now as indicated in the table below.

 

Macintosh System Requirements

 

For the latest information about System software and Studio Manager, please visit our website at:
www.yamahaproaudio.com. 

 

 

Save the Data from the 02R96

 

1.

 

Press the DISPLAY ACCESS [MIDI] key to open the Bulk Dump page.

 

2.

 

Set CATEGORY to ALL, select the TRANSMIT button, and then press the [ENTER] key to

start the save. 

 

Computer

A Macintosh G3/233 MHz or better and a USB port

OS

Mac OS 8.6 to 9.2.2 (Mac OS X not supported)

Memory

120 MB or more of free memory (Virtual memory must be turned off)

Hard Disk

7 MB or more

Display

1024 

 

×

 

 768 pixels, 256 colors or higher

1280 

 

×

 

 1024, 32,000 colors recommended

Other

OMS 2.3.3 or later

 

Note: If you are using a PowerBook on battery power, open the Energy Save
control panel, and in Advanced Settings, Additional Power Savings, turn off
Allow processor cycling.

 

The board installation procedure will clear all 02R96 user memory, and will reset all 02R96 settings to
their defaults. Before starting installation, use the following procedure to save the data from the 02R96
into an external MIDI device. You can then restore the data after completing the installation.

As an alternative, you can use Studio Manager to save the 02R96 data into a computer. For details,
refer to the Studio Manager owner’s manual (PDF file).

Содержание ME02R96

Страница 1: ...ard may lead to shock fire hazard or equipment failure Be sure to unplug the 02R96 main unit from the power supply before installing the ME02R96 board to eliminate shock hazard Be careful to avoid catching or snagging fingers while carrying out the installation Before starting installation be sure to save all important data from the 02R96 unit to an external MIDI device This installation process w...

Страница 2: ...o be the source of interference which can be determined by turning the unit OFF and ON please try to eliminate the problem by using one of the following measures Relocate either this product or the device that is being affected by the inter ference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference...

Страница 3: ...eri Eksplosionsfare ved fejlagtig håndtering Udskiftning må kun ske med batteri af samme fabrikat og type Levér det brugte batteri tilbage til leverandoren VARNING Explosionsfara vid felaktigt batteribyte Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt fabrikantens instruktion VAROITUS Paristo voi räjähtää jos se on virheellise...

Страница 4: ...SPLAY ACCESS MIDI key to open the Bulk Dump page 2 Set CATEGORY to ALL select the TRANSMIT button and then press the ENTER key to start the save Computer A Macintosh G3 233 MHz or better and a USB port OS Mac OS 8 6 to 9 2 2 Mac OS X not supported Memory 120 MB or more of free memory Virtual memory must be turned off Hard Disk 7 MB or more Display 1024 768 pixels 256 colors or higher 1280 1024 32 ...

Страница 5: ...e left and the other from the right To remove each panel remove 6 screws as shown below for a total of 12 screws For more information about SP02R96 side panels refer to the 02R96 owner s manual When removing each screw note its location and be sure to return it to the same place when reassem bling Screws come in various sizes and are not interchangeable This kit is not user installable Users shoul...

Страница 6: ...r bridge is installed on the 02R96 remove it First disconnect the bridge cable from the METER connector on the 02R96 Then remove the 4 screws holding the bridge in place as shown below and remove the bridge 2 Screws METER Connector 2 Screws 02R96 ...

Страница 7: ...screws if 2 were already removed at Step 3 from the rear 5 Hold onto the LCD and lift up the rear of the control panel 6 Secure the raised control panel in place so that it does not fall back down Rear View Positioning Screw Left Side View Position ing Screw LCD 7 Screws Top View 7 Screws Right Side View Front View 7 Screws Positioning Screw 7 Screws Position ing Screw LCD ...

Страница 8: ...nectors on the 02R96 Then fasten the ME02R96 into place using 4 screws the 4 screws you removed above or the 4 screws included in the kit 4 Reconnect the 2 flat cables To reconnect Push the latch down then insert the cable so that the red line on the cable is aligned with the mark on the board 5 Install the supplied lithium battery This is a backup battery that is required to maintain data in the ...

Страница 9: ... DISPLAY ACCESS MIDI key to open the Bulk Dump page 3 Set the CATEGORY to ALL select the REQUEST button and then press the ENTER key Kit Contents European models Purchaser User Information specified in EN55103 1 and EN55103 2 Conforms to Environments E1 E2 E3 and E4 Before screwing in the control panel check to make sure that you have not left any loose screws or tools inside the 02R96 casing Loos...

Отзывы: