1.  IMPORTANT NOTICE: DO NOT MOD-

IFY THIS UNIT!

This product, when installed as indicated 
in the instructions contained in this man-
ual, meets FCC requirements. Modifica-
tions not expressly approved by Yamaha 
may void your authority, granted by the 
FCC, to use the product.

2. IMPORTANT:

 When connecting this 

product to accessories and/or another 
product use only high quality shielded 
cables. Cable/s supplied with this prod-
uct MUST be used. Follow all installation 
instructions. Failure to follow instructions 
could void your FCC authorization to use 
this product in the USA.

3. NOTE:

 This product has been tested 

and found to comply with the require-
ments listed in FCC Regulations, Part 15 
for Class “B” digital devices. Compliance 
with these requirements provides a rea-
sonable level of assurance that your use 
of this product in a residential environ-
ment will not result in harmful interfer-
ence with other electronic devices. This 
equipment generates/uses radio fre-
quencies and, if not installed and used 
according to the instructions found in the 
users manual, may cause interference 

harmful to the operation of other elec-
tronic devices. Compliance with FCC 
regulations does not guarantee that 
interference will not occur in all installa-
tions. If this product is found to be the 
source of interference, which can be 
determined by turning the unit “OFF” 
and “ON”, please try to eliminate the 
problem by using one of the following 
measures:

Relocate either this product or the 
device that is being affected by the inter-
ference. 

Utilize power outlets that are on different 
branch (circuit breaker or fuse) circuits 
or install AC line filter/s.

In the case of radio or TV interference, 
relocate/reorient the antenna. If the 
antenna lead-in is 300 ohm ribbon lead, 
change the lead-in to co-axial type 
cable.

If these corrective measures do not pro-
duce satisfactory results, please contact 
the local retailer authorized to distribute 
this type of product. If you can not locate 
the appropriate retailer, please contact 
Yamaha Corporation of America, Elec-
tronic Service Division, 6600 Orangetho-
rpe Ave, Buena Park, CA90620

The above statements apply ONLY to those products distributed by Yamaha Corpora-
tion of America or its subsidiaries.

* This applies only to products distributed by YAMAHA CORPORATION OF AMERICA.

(class B)

FCC INFORMATION (U.S.A.)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation.

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Содержание ME02R96

Страница 1: ...ard may lead to shock fire hazard or equipment failure Be sure to unplug the 02R96 main unit from the power supply before installing the ME02R96 board to eliminate shock hazard Be careful to avoid catching or snagging fingers while carrying out the installation Before starting installation be sure to save all important data from the 02R96 unit to an external MIDI device This installation process w...

Страница 2: ...o be the source of interference which can be determined by turning the unit OFF and ON please try to eliminate the problem by using one of the following measures Relocate either this product or the device that is being affected by the inter ference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference...

Страница 3: ...eri Eksplosionsfare ved fejlagtig håndtering Udskiftning må kun ske med batteri af samme fabrikat og type Levér det brugte batteri tilbage til leverandoren VARNING Explosionsfara vid felaktigt batteribyte Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt fabrikantens instruktion VAROITUS Paristo voi räjähtää jos se on virheellise...

Страница 4: ...SPLAY ACCESS MIDI key to open the Bulk Dump page 2 Set CATEGORY to ALL select the TRANSMIT button and then press the ENTER key to start the save Computer A Macintosh G3 233 MHz or better and a USB port OS Mac OS 8 6 to 9 2 2 Mac OS X not supported Memory 120 MB or more of free memory Virtual memory must be turned off Hard Disk 7 MB or more Display 1024 768 pixels 256 colors or higher 1280 1024 32 ...

Страница 5: ...e left and the other from the right To remove each panel remove 6 screws as shown below for a total of 12 screws For more information about SP02R96 side panels refer to the 02R96 owner s manual When removing each screw note its location and be sure to return it to the same place when reassem bling Screws come in various sizes and are not interchangeable This kit is not user installable Users shoul...

Страница 6: ...r bridge is installed on the 02R96 remove it First disconnect the bridge cable from the METER connector on the 02R96 Then remove the 4 screws holding the bridge in place as shown below and remove the bridge 2 Screws METER Connector 2 Screws 02R96 ...

Страница 7: ...screws if 2 were already removed at Step 3 from the rear 5 Hold onto the LCD and lift up the rear of the control panel 6 Secure the raised control panel in place so that it does not fall back down Rear View Positioning Screw Left Side View Position ing Screw LCD 7 Screws Top View 7 Screws Right Side View Front View 7 Screws Positioning Screw 7 Screws Position ing Screw LCD ...

Страница 8: ...nectors on the 02R96 Then fasten the ME02R96 into place using 4 screws the 4 screws you removed above or the 4 screws included in the kit 4 Reconnect the 2 flat cables To reconnect Push the latch down then insert the cable so that the red line on the cable is aligned with the mark on the board 5 Install the supplied lithium battery This is a backup battery that is required to maintain data in the ...

Страница 9: ... DISPLAY ACCESS MIDI key to open the Bulk Dump page 3 Set the CATEGORY to ALL select the REQUEST button and then press the ENTER key Kit Contents European models Purchaser User Information specified in EN55103 1 and EN55103 2 Conforms to Environments E1 E2 E3 and E4 Before screwing in the control panel check to make sure that you have not left any loose screws or tools inside the 02R96 casing Loos...