Saving data to a USB storage device.

The scenes and set up of an M7CL console can be stored to an external USB storage device. This serves to back up the 

console’s internal memory and allow transfer of the data to another console in another territory. Files made on either the 

32-channel or 48-channel version will open in the other version.

Simply inserting a USB storage device will open the SAVE / LOAD pop-up screen.

If your stick is already connected then you can access the SAVE / LOAD pop-up from the [SETUP] button in the 

Function Access Area and then press the [SAVE/LOAD] button.

Pressing the [SAVE] button will result in an ALL DATA save. The 
text box explains what is included in that data file.

You can also access the CREATE USER KEY pop-up from this 
page. In addition to Administrator-set user access privileges 
the key stores your preferences and user defined key settings.  
So it’s a useful way to transfer user defined keys and 
preferences to another console when you are starting a new 
project.

Saved on USB storage device as ALL DATA file

All the scene data from the above list for all the scenes.

- The current scene

 (the scene in use at the time of 

save)

.

- External HA to slot assignment
- Safe assignments
- Work clock settings
- CUE pop-up settings 

(PFL trim inputs, DCA trim, 

PFL trim outputs)

- MONITOR pop-up settings

 (levels, source on/off, 

mono, link)

- Metering point selection
- MIDI settings
- OUTPORT settings 

(delay and level)

- User libraries
   

EQ/HPF

 (user and ROM)

   

Dynamics

 (not key-in) (user and ROM)

   

GEQ

 (user only)

   

Effects

 (user and ROM)

- User access level for Administrator and Guest
- Preferences for Administrator and Guest
- User defined keys for Administrator and Guest

Stored on user authentication key

- User access level
- Preferences
- User defined keys

Loading data to the console from a USB storage device.

When an ALL DATA file is loaded into a M7CL all the data in the console is over-written (except the few items like 

passwords in the text box below). Similarly if a LIB scenes-only file is loaded all existing scenes are over-written but 

setup data like user defined keys are retained. LIB files are discussed later.

Содержание M7CL StageMix V1.5

Страница 1: ...scene management saving and loading This guide is for people about to use the M7CL with multiple scenes for the rst time and for users who wish to transfer their console set ups to different M7CLs usi...

Страница 2: ...s or Recall Focus typical use examples 7 How scene recall can be limited a summary 7 What is in a scene 8 Saving and loading data 8 Saving data to a USB storage device 9 Loading data to the console fr...

Страница 3: ...raries of parameter information like the EQ GEQ and dynamics libraries and set up features like patch information user de ned key and other preferences Together all these memories add up to be a sessi...

Страница 4: ...red The scene number shows in the Function Access Area and the goes out until another desk change is made For really fast scene storing you can disable the con rmation in SETUP preferences Now a simpl...

Страница 5: ...memorized regardless of the consoles settings but when a scene is recalled with Recall Safe or Focus settings applied the speci c parameters of channels to be recalled are limited by those settings a...

Страница 6: ...button in the box above Channels with all parameters safed are shown green Channels with partial safes are shown blue There are many possible partial safe combinations but all are shown in blue It is...

Страница 7: ...t to understand that Focus differs from Recall Safe Recall Safe is global to all scenes and Focus is speci c to a particular scene Also the selectable parameters are different How scene recall can be...

Страница 8: ...puts MONITOR pop up levels source on off mono link Oscillator all parameters Safe assignments mute recall Passwords admin guest settings Screen page or pop up Sends on fader selected Metering point se...

Страница 9: ...d preferences to another console when you are starting a new project Saved on USB storage device as ALL DATA le All the scene data from the above list for all the scenes The current scene the scene in...

Страница 10: ...the M7CL Editor and these les can be used for transferring data between consoles and editors User Key M7U This is the user authentication key that carries the user preference and access information li...

Страница 11: ...to change most of the scene parameter data Notably the Editor cannot be used for the items in the following text boxes Cannot be set by M7CL Editor but still saved in M7C YSM or YSE les User de ned k...

Страница 12: ...ey appear as a LIB le in the console SAVE LOAD pop up To save the INTERNAL DATA scene list go to File Save Session and save to your computers memory The le can be saved either as an M7C le for transfe...

Страница 13: ...is online or the INTERNAL DATA can be saved to a USB storage device and transferred to the console that way In this way new scenes can be introduced to an existing session without loss of audio or int...

Страница 14: ...Revision History M7CL Quick Start Guide Part 3 Month Year Version Contents April 2007 1 0 First edition released...

Отзывы: