background image

10/13

M7CL Quick Start Guide Part 3

Other memorized data.

Some things are memorized by the console but not included in the ALL DATA file. And some things are not memorized 

by the console at all.

Memorized at power down on the console but not 
in ALL DATA file

- Passwords
- Screen page
- Brightness controls
- Network settings
- Clock

 (time/date etc)

Not stored anywhere!

- Screen page pop-up

 (but can be bookmarked)

- Talkback on
- Talkback dimmer on
- Cue on
- Osc on

 (always off at power up)

- Monitor dimmer on
- Console lock
- Monitor, talkback and headphone pots

 (but 

shouldn’t move in transit!)

Management of M7CL console files.

In the SAVE / LOAD pop-up, you can COPY, PASTE and DELETE items on your USB storage device, regardless of 

what kind of file they are. However, only certain kinds of file can be loaded into M7CL. Only ALL DATA and USER 

KEY files can be created on M7CL but Studio Manager M7CL Editor can save “scene-only” data. There are also 

firmware files and help menu files to recognize. See the guide below.

How files appear in M7CL.

M7CL files.

All.M7C:

 This is an ALL DATA console set-up file that 

includes all the information listed in the text box on page 

9. All.M7C files can be created on either the console or the 

M7CL Editor and these files can be used for transferring 

data between consoles and editors.

User Key.M7U:

 This is the user authentication key that 

carries the user preference and access information listed on 

page 9. The user access privileges may be created, viewed 

and edited on the console or the editor, but only the console 

can view and edit the preferences and user defined keys.

LIB.M7C: 

This is a file of “scene-only” data created within 

the Studio Manager. It does not include other non-scene 

recallable data like user defined keys or EQ etc libraries.

Firmware.PGM files:

 There are two different .PGM files 

that make up the console firmware but these will self load 

at switch on. (With a confirm dialog pop-up) They cannot 

be loaded from the SAVE / LOAD pop-up.

M7CL_EN.XML:

 There are several different language help 

files available and these must be loaded from the SAVE / 

LOAD pop-up.

???.YSE: 

This is a Yamaha Studio Editor session file created 

and stored in the Editor software and it will not open in the 

console, only the editor.

New.M7C:

 Sessions saved on newer versions of Studio 

Manager appear as “New” on old console firmware. Update 

your firmware to access them.

How files appear in MS Windows.

Note; There are two types of .M7C files; ALL and LIB. An ALL DATA or USER KEY file created on Studio Manager 

will have the default settings for user defined keys until saved on a console with edited UDKs.

Содержание M7CL StageMix V1.5

Страница 1: ...scene management saving and loading This guide is for people about to use the M7CL with multiple scenes for the rst time and for users who wish to transfer their console set ups to different M7CLs usi...

Страница 2: ...s or Recall Focus typical use examples 7 How scene recall can be limited a summary 7 What is in a scene 8 Saving and loading data 8 Saving data to a USB storage device 9 Loading data to the console fr...

Страница 3: ...raries of parameter information like the EQ GEQ and dynamics libraries and set up features like patch information user de ned key and other preferences Together all these memories add up to be a sessi...

Страница 4: ...red The scene number shows in the Function Access Area and the goes out until another desk change is made For really fast scene storing you can disable the con rmation in SETUP preferences Now a simpl...

Страница 5: ...memorized regardless of the consoles settings but when a scene is recalled with Recall Safe or Focus settings applied the speci c parameters of channels to be recalled are limited by those settings a...

Страница 6: ...button in the box above Channels with all parameters safed are shown green Channels with partial safes are shown blue There are many possible partial safe combinations but all are shown in blue It is...

Страница 7: ...t to understand that Focus differs from Recall Safe Recall Safe is global to all scenes and Focus is speci c to a particular scene Also the selectable parameters are different How scene recall can be...

Страница 8: ...puts MONITOR pop up levels source on off mono link Oscillator all parameters Safe assignments mute recall Passwords admin guest settings Screen page or pop up Sends on fader selected Metering point se...

Страница 9: ...d preferences to another console when you are starting a new project Saved on USB storage device as ALL DATA le All the scene data from the above list for all the scenes The current scene the scene in...

Страница 10: ...the M7CL Editor and these les can be used for transferring data between consoles and editors User Key M7U This is the user authentication key that carries the user preference and access information li...

Страница 11: ...to change most of the scene parameter data Notably the Editor cannot be used for the items in the following text boxes Cannot be set by M7CL Editor but still saved in M7C YSM or YSE les User de ned k...

Страница 12: ...ey appear as a LIB le in the console SAVE LOAD pop up To save the INTERNAL DATA scene list go to File Save Session and save to your computers memory The le can be saved either as an M7C le for transfe...

Страница 13: ...is online or the INTERNAL DATA can be saved to a USB storage device and transferred to the console that way In this way new scenes can be introduced to an existing session without loss of audio or int...

Страница 14: ...Revision History M7CL Quick Start Guide Part 3 Month Year Version Contents April 2007 1 0 First edition released...

Отзывы: