HY144-D-SRC Firmware Update Guide
9
HY144-D-SRC is installed, and restart the procedure from
the step 3. If update still fails, follow the instructions stated
in “About Failsafe Mode” to perform the recovery process.
10.
Turn off the power to the device to which
the HY144-D-SRC is installed, and then on
again.
NOTE
Rapidly turning the unit on and off in succession can cause
it to malfunction. After turning the unit off, wait for at least
few seconds before turning it on again. Refer to the owner’s
manual supplied with each device for how much time
should elapse between turning the power off and on again.
11.
Windows:
Select [Start]→[All programs]
or [All apps]
→[Audinate]→[Dante
Controller
]→[Dante
Controller] , then
right-click and select [Run as
Administrator].
Mac:
[Application]→[Dante
Controller],
then double-click “Dante Controller.”
The Dante Controller will start up.
NOTE
The “User Account Control” dialog box may appear. Click
[Continue] or [Yes].
12.
Perform the “Clear Config” operation to
initialize the HY144-D-SRC.
NOTE
When you change the SRC mode, the settings before the
mode change may still be present and the device may not
work properly. To prevent this problem, take a note of the
Dante settings in advance, initialize all the Dante settings
using “Clear Config,” and then set them again manually.
For details on instruction, refer to the Dante
Controller User Guide available on the
following website:
https://www.yamaha.com/proaudio/
The firmware update is now complete.