Cause:
The temperature of the heatsink is excessive.
Supplementary information:
The protection function worked due to the temperature limit being exceeded. Causes could
be poor ventilation or a defect related to the thermal sensor.
Turning on the power without correcting the abnormality will cause the protection function to work in 1 seconds and the
power supply will be shut off.
2-4. When the protection function worked due to excessive heatsink temperature.
●
History of protection function
When the protection function has worked, its history is stored in memory with a backup.
Even if no abnormality is noted while servicing the unit, an abnormality which has occurred previously can be defined
as long as the backup data has been stored.
For details, refer to “P2 PROTECTION HISTORY” menu.
T M P 1 P R T : x x x L