21. PROTECTION HISTORY
This menu is used to display the history of protection function.
All history of protection function will be erased by pressing the “STRAIGHT” key.
*
Numeric values in the figure are given as reference only.
Example
Example
Example
Example
2 1 - 1 . P S 1 0 7 8 L
2 1 - 2 . D c 1 2 6 H
2 1 - 3 . T m p 0 0 0 L
2 1 - 4 . I 0 0 0 H
21-1. History 1
H: When the upper limit of the protection function is exceeded.
L: When the lower limit of the protection function is exceeded.
A/D value when the protection function is activated. (Reference voltage: 3.3 V=255)
21-2. History 2
21-3. History 3
21-4. History 4
43
RX-V371/HTR-3064
RX-V371/HTR-3064