Display provided when Self-Diagnostic Function started
The display is as described below depending on the situation the last time the power to this unit is turned off.
1. When the power is turned off normally:
“NO PROTECT” is displayed. “1. ANALOG BYPAS” menu is displayed in a few seconds.
2. When the protection function worked to turn off the power:
The data of protection function which worked at the moment “1.ANALOG BYPAS” menu is displayed in a few seconds.
Note: At the time if you reactivate the self-diagnostic function after turning off the power once by pressing the “ ” (Power)
key, “NO PROTECT” will be displayed because that situation is equal to “1. When the power is turned off by usual
operation:” described above.
However the protection function history is stored in a back-up IC with a backup. For details, refer to “21.
PROTECTION HISTORY” menu.
2-1. When the protection function worked due to excess current.
N O P R O T E C T
1 . A N A L O G B Y P A S
Cause:
An excessive current flowed through the power amplifier.
Supplementary information:
As current of the power amplifier is detected, the abnormal channel can be identified by
checking the current detect transistor.
Turning on the power without correcting the abnormality will cause the protection function to work immediately and the
power supply will instantly be shut off.
After a few seconds
Main menu display
Opening message
P S P R T : x x x L
Notes)
• Applying the power to this unit without correcting the abnormality can be dangerous and cause additional
circuit damage. To avoid this, if “PS” and “DC” protection function works 3 times consecutively, the power will
not turn on even when the “ ” (Power) key is pressed.
In order to turn on the power again, disconnect the power cable of this unit from the AC outlet once and then
reconnect it again.
•
The output transistors in each amplifier channel should be checked for damage before applying power to this unit.
•
Amplifier current should be monitored by measuring DC voltage across the emitter resistors for each channel.
AD value when the protection function is working
26
RX-V371/HTR-3064
RX-V371/HTR-3064
Содержание HTR-3064 Series
Страница 4: ...HTR 3064 U C T models HTR 3064 R K A G F L S models 4 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 6: ...RX V371 K model RX V371 A model RX V371 B G F models 6 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 7: ...RX V371 L model HTR 3064 U C models HTR 3064 R S models 7 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 8: ...HTR 3064 A model HTR 3064 T model HTR 3064 K model 8 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 9: ...HTR 3064 G F models HTR 3064 L model 9 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 100: ... ADVANCED SETUP U C models RX V371 HTR 3064 101 ...
Страница 101: ...R T K A B G F L S models R T K A L S models B G F models RX V371 HTR 3064 102 ...
Страница 102: ...103 RX V371 HTR 3064 RX V371 HTR 3064 MEMO ...
Страница 103: ...RX V371 HTR 3064 ...