Fig. 6
Fig. 5
⑪
⑩
⑩
⑩
G3
Ground lead
Heatsink
MAIN (1) P.C.B.
Ground lead
Chassis
Rear panel
When checking the MAIN (1) P.C.B.
a. Remove the top cover. (Fig. 1)
b. Remove 3 screws (
⑨
). (Fig. 3)
c. Remove 5 screws (
⑩
) and 4 screws (
⑪
). (Fig. 5)
d. Place the P.C.B.s (with rear panel) upright. (Fig. 6)
e. Connect the heatsink, rear panel and MAIN (1) P.C.B. (G3) to the chassis with a ground lead or the like. (Fig. 6)
When checking the DIGITAL P.C.B.
• Put the rubber sheet and cloth over this unit, and place the DIGITAL P.C.B. on them. (Fig. 4)
• Connect ST201 on DIGITAL P.C.B. to the chassis with a ground lead or the like. (Fig. 4)
• Reconnect all cables (connectors) that have been disconnected. Be sure to use the P.C.B. CHECKING JIG (Part No.
WW483800) to connect between the following connectors.
CB263 on DIGITAL P.C.B. – CB196 on OPERATION (4) P.C.B.
CB264 on DIGITAL P.C.B. – CB195 on OPERATION (4) P.C.B.
• When connecting the flexible flat cable, be careful with polarity.
Fig. 4
DIGITAL P.C.B.
OPERATION (4) P.C.B.
P.C.B. CHECKING JIG
CB263
CB264
CB196
CB195
Rubber sheet and cloth
ST201
Ground lead
Chassis
19
RX-V371/HTR-3064
RX-V371/HTR-3064
Содержание HTR-3064 Series
Страница 4: ...HTR 3064 U C T models HTR 3064 R K A G F L S models 4 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 6: ...RX V371 K model RX V371 A model RX V371 B G F models 6 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 7: ...RX V371 L model HTR 3064 U C models HTR 3064 R S models 7 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 8: ...HTR 3064 A model HTR 3064 T model HTR 3064 K model 8 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 9: ...HTR 3064 G F models HTR 3064 L model 9 RX V371 HTR 3064 RX V371 HTR 3064 ...
Страница 100: ... ADVANCED SETUP U C models RX V371 HTR 3064 101 ...
Страница 101: ...R T K A B G F L S models R T K A L S models B G F models RX V371 HTR 3064 102 ...
Страница 102: ...103 RX V371 HTR 3064 RX V371 HTR 3064 MEMO ...
Страница 103: ...RX V371 HTR 3064 ...