ELEC
Electrical system
–
+
8-27
67C3K11
3.
Check the Rectifier Regulator for conti-
nuity. Replace if out of specification.
NOTE:
The voltage values given in the table are for
reference only. If voltage is produced, there
is continuity, and, if there is an overload,
there is no continuity. Refer to the table to
determine if there should or should not be
continuity and replace the Rectifier Regulator
if out of specification.
NOTE:
Be sure to set the measurement range
a
,
and display the mark
b
by pushing the
“SHIFT” switch when checking the Rectifier
Regulator continuity.
OL: Indicates an overload
S67C8060
5
R
3
Y1
6
B
Gy
4
Y2
Y2
4
Y1
3
Gy
R
5
B
6
S6S18360
a
b
Rectifier Regulator continuity
(testing diode)
Tester lead
Display value (V)
(reference data)
Conti-
nuity
+
-
Y1
3
R
5
0.447
Yes
Y1
3
B
6
1.503
Yes
Y1
3
Y2
4
OL
No
Y2
4
R
5
0.439
Yes
Y2
4
B
6
1.502
Yes
Y2
4
Y1
3
OL
No
B
6
R
5
0.416
Yes
B
6
Y1
3
OL
No
B
6
Y2
4
OL
No
R
5
B
6
OL
No
R
5
Y1
3
OL
No
R
5
Y2
4
OL
No
Содержание F30A
Страница 1: ...F30A F40B SERVICE MANUAL 67C 28197 3K 11 ...
Страница 4: ......
Страница 26: ...GEN INFO General information 1 21 67C3K11 MEMO ...
Страница 150: ...POWR Power unit 5 55 67C3K11 MEMO ...
Страница 172: ...LOWR Lower unit 6 21 67C3K11 Shimming S67C6063 T1 T2 B2 A2 F R P T3 B3 A3 42 0 T1 T2 B1 28 0 28 0 B2 A2 A1 ...
Страница 236: ...BRKT Bracket unit 7 55 67C3K11 MEMO ...
Страница 282: ......
Страница 283: ...YAMAHA MOTOR CO LTD Printed in China Aug 2007 1 2 1 CR E ...