– 20 –
761-081a
762-042
1
2
12v
762-043a
763-238a
q
w
AE00825
Battery Charging
NOTE:
The generator DC rated voltage is 12V.
1. Wind the battery charging lead (furnished as an
accessory) 2 or 3 turns around the handle and plug
into DC receptacle.
NOTE:
9
Make connections to the battery after starting the
engine.
9
Clamp the red wire to the positive (+) terminal and
the black wire to the negative (-) terminal of the
battery. Do not reverse these positions.
1
Red
2
Black
2. Start the engine.
3. Press in the DC protector and install the battery.
c
C
9
Be sure the battery leads are properly connect-
ed.
9
Be sure the breather hose is properly connect-
ed and is not damaged or obstructed.
9
Reduce the load to the specified generator
rated output if the DC protector turns off. If it
turns off again, consult a Yamaha dealer.
NOTE:
Press to reset the DC protector.
1
“ON”
2
“OFF”
NOTE:
9
At full charge, electrolyte specific gravity is
between 1.26 and 1.28.
9
Check specific gravity hourly.