![Yamaha EF3000iSE - Inverter Generator - 3000 Maximum AC Output Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/yamaha/ef3000ise-inverter-generator-3000-maximum-ac-output/ef3000ise-inverter-generator-3000-maximum-ac-output_service-manual_901747033.webp)
2-21
INSP
ADJ
DC CIRCUIT BREAKER/
DC CIRCUIT BREAKER (120 V-60 Hz)
DC CIRCUIT BREAKER
1. Check:
• DC circuit breaker
Checking steps:
• Check if the DC circuit breaker knob
1
is
set to “RESET” “
”
a
.
• If the knob
1
is set to “OFF” “
”
b
,
direct current cannot be supplied.
• Start the engine.
• Connect a pocket tester (DC 20 V) to the
DC receptacle and check if direct current
is supplied.
Direct current not supplied
→
Replace or
refer to “GENERATOR SYSTEM” in
CHAPTER 4.
Pocket tester:
YU-03112-C, 90890-03112
1
a b
SWL2080T
SWL2090T
DC CIRCUIT BREAKER (120 V-60 Hz)
1. Check:
• DC circuit breaker
Checking steps:
• Set the DC circuit breaker
1
to the posi-
tion of “ON”
a
.
• Connect the pocket tester (DC 20 V).
• Start the engine.
• Set the economy switch to “OFF”.
• Measure the DC voltage.
• Set the DC circuit breaker
1
to “OFF”
b
.
Voltage is zero
→
OK
Pocket tester:
YU-03112-C, 90890-03112
DC voltage:
More than 12 V at 3,550 r/min
(no load at AC output current)
DC
ON
OFF
ON
1
a
b
SVU2330C
SWL2100T