5-2
SPEC
GENERAL SPECIFICATIONS
Electrical:
Ignition system
TCI
Spark plug type
BPR4ES (NGK)
Gap
mm (in)
0.7 ~ 0.8 (0.028 ~ 0.031)
Generator:
Type
Multi pole rotating field magnet
Initial excitation
Permanent magnet
Driving method
Direct connection
Rated power factor
1.0
Frequency variation
Instantaneous
Less than 1%
Settling
Less than 0.1%
Settling time
Less than 1 sec
Voltage fluctuation
Instantaneous
Less than 20%
Settling
Less than 3%
Settling time
Less than 2 sec
AC output
Rated voltage
V
120 (120 V-60 Hz)
220 (220 V-50 Hz)
230 (230 V-50 Hz)
Frequency
Hz
50 (220 V-50 Hz, 230 V-50 Hz)
60 (120 V-60 Hz)
Rated output
kVA
2.8
Rated current
A
23.3 (120 V-60 Hz)
12.7 (220 V-50 Hz)
12.2 (230 V-50 Hz)
DC output
Rated voltage
V
12
Rated current
A
8.3 (120 V-60 Hz)
12 (220 V-50 Hz, 230 V-50 Hz)
Safety device type
AC
Electronic no fuse breaker
DC
Circuit breaker (No fuse breaker)
Engine speed (no load)
r/min
3,550
Rated engine speed
r/min
3,800
Economy engine speed (no load)
r/min
2,800 ± 50
Voltage regulation
Voltage feed back system
Voltage stability
Within ± 4%
Frequency stability
Hz
Within ± 1.0
Rotating speed control
Throttle motor control type
Wave distortion ratio
Less than 2.5%
Unit
EF3000iSE