30
DXS12/DXS15
3-5. SWITCH inspection
Inspect INVT | NORM status of POLARITY switch.
Inspect on | off status of FRONT LED DISABLE switch.
Inspect BOOST | OFF | XTENDED-LF status D-XSUB
switch.
Inspect 120 Hz | 100 Hz | 80 Hz status of LPF switch.
Set status of each switch according to the display and click
“OK” button.
3-4. A-MUTE inspection
Conduct level check when analog mute (SP OUT side).
Input measuring result on A-MUTE test.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value PASS
PASS: A-MUTE LEVEL
When Abnormal
Measurement value FAIL
FAIL: A-MUTE LEVEL
Troubleshooting
If FAIL, check AMPSW circuit board.
3-5. SWITCH
検査
POLARITY スイッチ の INVT ¦ NORM 状態を検査し
ます。
FRONT LED DISABLE スイッチ の ON ¦ OFF 状態
を検査します。
D-XSUB スイッチ の BOOST ¦ OFF ¦ XTENDED-LF
状態を検査します。
LPF スイッチ の 120 Hz ¦ 100 Hz ¦ 80 Hz 状態を検査
します。
画面表示に従って各スイッチの状態を設定し、
「OK」
ボタンをクリックします。
3-4. A-MUTE
検査
アナログミュート時(SP OUT 側)のレベル確認を
行います。
A-MUTE テストでの計測結果を入力します。
結果が PASS の場合、
「Yes」ボタンをクリックします。
結果が FAIL の場合、
「No」ボタンをクリックします。
オペレータの計測結果に応じた結果判定を入力する
と、検査結果はアウトプットウインドウへ下記のよ
うに表示されます。
正常時
計測値 PASS
PASS:
A-MUTE LEVEL
異常時
計測値 FAIL
FAIL:
A-MUTE LEVEL
トラブルシューティング
FAIL の場合、AMPSW シートを確認してください。
Содержание DXS Series
Страница 6: ...DXS12 DXS15 6 O 03 66 0 アンプAss y 1 DC ファン 68 68 68 68 036 63 ...
Страница 7: ...7 DXS12 DXS15 DIMENSIONS 寸法図 478 618 624 397 563 594 DXS12 DXS15 Unit 単位 mm Unit 単位 mm ...
Страница 21: ...21 DXS12 DXS15 Pattern side パターン側 AMPSW Circuit Board Scale 90 100 2NA WW65240 2 ...
Страница 23: ...23 DXS12 DXS15 2NA WW59820 3 Pattern side パターン側 DSPW Circuit Board to AMPSW CN255 ...
Страница 58: ...190 170 160 200 220 230 250 360 370 350 370 210 10d 240 Details A A 部詳細 380 7 DXS12 DXS15 ...
Страница 59: ... E E F F D F E E E E E E E D E E 6 66 0 シールド Ass y 03 29 5 66 0 アンプカバー Ass y DXS12 DXS15 8 ...