background image

 

Notes for DME64N/DME24N Version 1.2

 

6

 

Message List

 

Message

Content

Corrective Action

 

Cannot Select

There is no selectable item in the scene or monitoring 
point list. 

Data is not registered.Register the data to be used in DME 
Designer.

CAS. In Sync Err

The word clock input from the [CASCADE IN] terminal is 
not synchronized with the DME64N word clock. 

Recheck the settings for using the word clock that 
synchronizes the DME64N and external devices. 

CAS. Out Sync Err 

The word clock input from the [CASCADE OUT] terminal is 
not synchronized with the DME64N word clock. 

Recheck the settings for using the word clock that 
synchronizes the DME64N and external devices. 

Connecting

Searching for DMEs in the network and connecting them. 

Download Success

The DME64N/24N program update or restoration was 
successful. 

Downloading

Updating the DME64N/24N program. Do NOT turn off the 
power while this display is on the screen. 

DSP Power Shortage

The audio signal is muted without being input or output, 
because the DSP resources are insufficient. This message 
may be displayed when a configuration created at 44.1 or 
48 kHz is operated at 88.2 or 96 kHz. 

To operate with all word clocks, set the word clock in DME 
Designer to 96 kHz when creating a configuration. 

Duplicate IP Adr. 

An IP address is duplicated.

Change the settings so that there are no duplicate IP 
address. 

File Operating

Scene-related data (configuration, component, etc.) from 
the computer is in operation. Do NOT turn off the power 
while this display is on the screen. 

Flash Rom Full

The flash memory used for saving data has become full. 

Erase unused data such as configurations, presets, and 
audio data. 

Illegal MAC Adr.

This is an invalid MAC address. 

Since this is likely to be a device failure, contact a Yamaha 
electric sound service outlet listed at the end of this 
manual (page 79). 

Invalid IP Adr.

An IP address is invalid.

Set a valid IP address.

Invalid Password

The password is incorrect. 

Enter the correct password. If you have forgotten the 
password, contact a Yamaha electric sound service outlet 
listed at the end of this manual (page 79). 

Low Battery

Battery capacity is running low. 

Stop using the unit immediately and contact a Yamaha 
electric sound service outlet listed at the end of this 
manual (page 79). 

MIDI Port In Use

The USB port being used for communication with DME 
Designer has been selected as a host. 

Set Host on the utility screen’s MIDI page to another port. 

Network Busy

Traffic in the network is congested. Communication will 
take time. 

Check the devices connected to the network. If there are a 
large number of connected devices, reduce their number. 
If LinkMode is set to 10BASE-T, traffic speed may improve 
if the setting is changed to 100BASE-TX.

Network Error

An error like the following has occurred on the network: 
• A cable has become disconnected.
• The power to a connected hub or router is cut off.
• A cable is in an unsuitable condition (such as something 

heavy resting on the cable).
(Static electricity may be having an effect.)

Investigate the cause of the error and eliminate it.

Network Setup

Various settings for connecting to the network are being 
made. 

No Battery

The battery is exhausted. 

When the power is turned OFF, the current settings will be 
lost and the unit will return to its initial settings. Stop using 
the unit immediately and contact a Yamaha electric sound 
service outlet listed at the end of this manual (page 79). 

No Current Scene

There is no current scene.

This is displayed when scene data has not been sent even 
once. Create data using DME Designer, and synchronize 
DME Designer and the DME64N/24N unit. 

No MAC Adr.

No MAC address is set.

Since this is likely to be a device failure, contact a Yamaha 
electric sound service outlet listed at the end of this 
manual (page 79). 

Panel Locked

Panel lock is set, and the panel cannot be operated. 

Panel lock may have been set by the administrator to 
prevent unexpected data changes caused by erroneous 
user operations. 
To use the panel, hold the [CANCEL] button down for at 
least two seconds. This clears the panel lock.

Panel Unlocked

Panel lock has been cleared. Panel operations are 
possible. 

Param Access Err

Cannot display current settings. 

The component version may be old. Update to the latest 
component. 

Param Set Err

Cannot change current settings. 

The component version may be old. Update to the latest 
component. 

Содержание DME24N

Страница 1: ...ha Pro Audio website http www yamahaproaudio com Added parameters are shown in bold Upgrading Cautions The following parameter will not be reflected in Version 1 2 when it is used to read data created...

Страница 2: ...and restarts A THRU connection function has been added Even in an environment with no computer you can check the connections without using DME Designer by directly connecting the DME64N 24N input outp...

Страница 3: ...rol Mode Switches to Final Output Stage Parameter Control Mode BANK BANK The channels targeted for operation are shifted by the number of channels built into the DAW controller CH CH The channels targ...

Страница 4: ...E64N 24N Owner s Manual has been changed By editing the Monitoring Point List in DME Designer you can select user defined monitoring points in the DME64N 24N Using this function component input output...

Страница 5: ...onents other than input output components cannot be arranged The following notes apply when Preparation on page 19 of the DME64N 24N Owner s Manual is started up for the first time The meter does not...

Страница 6: ...his manual page 79 Low Battery Battery capacity is running low Stop using the unit immediately and contact a Yamaha electric sound service outlet listed at the end of this manual page 79 MIDI Port In...

Страница 7: ...ot synchronized with the DME64N word clock Recheck the settings for using the word clock that synchronizes the DME64N and external devices SLOT3 Sync Err The word clock input from Slot3 is not synchro...

Страница 8: ...lip OUTPUT 1 8 150 600 Lines 4dBu 1 23V 24dBu 12 28 Euroblock PHONES 15 8 75mW 150mW Stereo Phone Jack 40 65mW 150mW Input Output RL Conditions Min Typ Max Units CH INPUT 1 8 CH OUTPUT 1 8 600 GAIN 60...

Отзывы: