Yamaha DME24N Скачать руководство пользователя страница 3

 

3

 

Notes for DME64N/DME24N Version 1.2

 

MODE: Summing

 

Sums all input signals coming from Inputs (-12dB), without regard to 
device or card type, and outputs it through all Outputs. 

 

 

The Event Scheduler function allows day/time settings for events

 

The settings are accessible via the Utility display “Misc” page.
Refer to the “DME Designer Version 1.2 Owner’s Manual” for details.

 

Event Scheduler

 

Determines whether an event schedule setup in the DME Designer 
will be executed or not, and displays the current status.

 

ON:

 

 The event will be executed.

 

OFF:

 

 The event schedule will not be executed.

 

 

A DAW control function has been added.

 

With this function you can control the DME64N/24N from a DAW controller. 

 

1. Parameter Control Function

 

Lets you control DME64N/24N parameters using a DAW Controller.
For example, if the PAN parameter is assigned to CH1 of the DAW controller, you can control the PAN parameter by 
operating a knob.

There are two modes in the parameter control function, as follows: 

(1) General Parameter Operation Mode

[KNOB] and [CH FADER] controls are used to operate internal parameters assigning them in DME Designer. 
For detailed settings, see the “DME Designer Version 1.2 Owner’s Manual.”

(2) Final Output Stage Parameter Operation Mode

Final output stage parameters are operated using [MUTE] and [CH FADER] controls. 
Unlike the General Parameter Control Mode, controls and the parameters that are compatible with them, are fixed in this 
mode.

[Method of Operation]

 

[

 

 

]:

 

 Switches to General Internal Parameter Control Mode. 

 

[

 

 

]:

 

 Switches to Final Output Stage Parameter Control Mode. 

 

[BANK <][BANK >]:

 

 The channels targeted for operation are shifted by the number of channels built into the DAW 

controller. 

 

[CH <][CH >]:

 

 The channels targeted for operation are shifted one channel at a time. 

 

[SELECT]:

 

 Switches the display method on the DAW controller. 

When turned OFF, an overall display appears. When a channel is turned ON, the detail display appears for that channel. 
For information about the overall and detail displays, see the next item, “Setting and Parameter Name Display Function.”

 

[KNOB]:

 

 Changes assigned parameters in the General Internal Parameter Operation Mode. 

This is not used in the Final Output Stage Parameter Operation Mode. 

 

[MUTE]:

 

 This is not used in the General Internal Parameter Operation Mode. 

This turns muting ON or OFF for the corresponding channel in the Final Output Stage Parameter Operation Mode. 

 

[CH FADER]:

 

 Changes assigned parameters in the General Internal Parameter Operation Mode. 

This adjusts volume for the corresponding channel in the Final Output Stage Parameter Operation Mode. 

 

2. Setting and parameter name display function

 

Displays the settings and parameter names on the DAW controller’s LCD screen. 
There are two display methods: over-all display and detail display. 

 

Overall Display:

 

 The overall display shows the assigned parameter names and settings, organized by DAW channels. 

 

Detail Display:

 

 In the detail display, you select the parameter you want to display. Only information for that parameter 

appears on the DAW controller’s LCD screen. 

 

NOTE

 

Only one parameter can be assigned to the same channel.

 

NOTE

 

The number of characters that can be displayed is limited by the size of the DRAW’s LCD screen.

Содержание DME24N

Страница 1: ...ha Pro Audio website http www yamahaproaudio com Added parameters are shown in bold Upgrading Cautions The following parameter will not be reflected in Version 1 2 when it is used to read data created...

Страница 2: ...and restarts A THRU connection function has been added Even in an environment with no computer you can check the connections without using DME Designer by directly connecting the DME64N 24N input outp...

Страница 3: ...rol Mode Switches to Final Output Stage Parameter Control Mode BANK BANK The channels targeted for operation are shifted by the number of channels built into the DAW controller CH CH The channels targ...

Страница 4: ...E64N 24N Owner s Manual has been changed By editing the Monitoring Point List in DME Designer you can select user defined monitoring points in the DME64N 24N Using this function component input output...

Страница 5: ...onents other than input output components cannot be arranged The following notes apply when Preparation on page 19 of the DME64N 24N Owner s Manual is started up for the first time The meter does not...

Страница 6: ...his manual page 79 Low Battery Battery capacity is running low Stop using the unit immediately and contact a Yamaha electric sound service outlet listed at the end of this manual page 79 MIDI Port In...

Страница 7: ...ot synchronized with the DME64N word clock Recheck the settings for using the word clock that synchronizes the DME64N and external devices SLOT3 Sync Err The word clock input from Slot3 is not synchro...

Страница 8: ...lip OUTPUT 1 8 150 600 Lines 4dBu 1 23V 24dBu 12 28 Euroblock PHONES 15 8 75mW 150mW Stereo Phone Jack 40 65mW 150mW Input Output RL Conditions Min Typ Max Units CH INPUT 1 8 CH OUTPUT 1 8 600 GAIN 60...