7. Pass Numbers and Error Messages
1 PASS NUMBER
PEDAL PASS NUMBERS
* Pedal measurement should always be done after finishing the above countermeasures
KEYBOARD PASS NUMBERS
THE PLAYBACK TABLE CONDITIONS WHICH ARE USED WHEN PASS HAS OCCURED
PASS No.
Message
Causes
Countermeasure
Pedal play-
back mode
Sustain Soft/shift
0
1 LOUD(SOFT)
CHECK SUM ERROR
Data has been erased or corrupted
Measure again
SW
2
— ADJUST LOUD PEDAL Too much of lost motion
for sustain pedal
Pedal acoustic adjustment
SW
3
— ADJUST LOUD PEDAL Too little lost motion
for sustain pedal
Pedal acoustic adjustment
SW
6
7 LOUD(SOFT)
SENSOR ERROR
Pedal A/D value = 0
Pedal measurement
Check the sensor condition
SW
8
9 LOUD(SOFT)
PEDAL OVER WEIGHT
The pedal is too heavy
Pedal acoustic adjustment
SW
10
11 LOUD(SOFT)
SENSOR ERROR
Unusual sensor condition
Pedal is depressed during measuerment
Pedal measurement
Check the sensor condition
SW
124
— ADJUST HALF POINT
Pedal half point could not be found
Perform the half point
measurement
HP
127
127
Normal
HP
PASS No.
Condition
Countermeasures
00
Nomal
01
02
03
04
Pedal movement problem
Acoustic adjustment problem
Hammer sensor problem
Pedal acoustic adjustment, Pedal measurement
Piano acoustic adjustment
Check the hammer sensor (sensor test)
10, 20, 30
Key drive problem
Hammer sensor problem
Check key drive unit
Check the hammer sensor (sensor test)
11, 21, 31
12, 22, 32
13, 23, 33
14, 24, 34
Pedal movement problem
Acoustic adjustment problem
Hammer sensor problem
Pedal acoustic adjustment, Pedal measurement
Piano acoustic adjustment
Check the hammer sensor (sensor test)
15, 25, 35
Acoustic adjustment problem
Key sensor problem
Piano acoustic adjustment
Check the key sensor (sensor test)
16, 26, 36
17, 27, 37
18, 28, 38
Acoustic adjustment problem
Pedal movement problem
Piano acoustic adjustment
Pedal acoustic adjustment, Pedal measurement
19, 29, 39
Connector problem
while the power is ON
Perform each measurement again
PASS No.
Condition
00
All kinds of measurement phases (5 kinds) were used when calculating
01~03
4 kinds of measurement phases were used
04
3 kinds of measurement phases were used
10~19
The same table data of the next (black/white) before was used
20~29
The same table data of the next but one (black/white) before was used
30~39
Emergency table data was used