CDC-E500
CDC-E500
25
Command
Function
16:10 Kick R
10 Kick in the inside direction is repeated every 30msec.
17:10 Kick F
10 Kick in the outside direction is repeated every 30msec.
18:30 Kick R
30 Kick in the inside direction is repeated every 40msec.
19:30 Kick F
30 Kick in the outside direction is repeated every 40msec.
20:150Kick R
150 Kick in the inside direction is repeated every 50msec.
21:150Kick F
150 Kick in the outside direction is repeated every 50msec.
22:Product M
It exits the test mode, and changes to the nominal mode.
23:Error Msg
The error message is displayed.
24:Test Rep
Test repeat is started. (not for service)
25:Test Coef
The following servo establishment value is indicated. It is changed by >>| and |<<.
FG / FEXP / FBAL / FOFS / TG / TEXP / TBAL / TOFS / FC / FR / TC / TR / FC2 / TC2 / TR2 / GSET /
VSET / SET0 / SET1 / SET2 / TOS2 / FES / TES / CRM2 / SD / KS / SET3
26:Mute Chg
Mute switching (digital, analog or both).
27:FcsG Chg
Focus gain is changed to normal or high.
28:MechaTest The mechanism endurance test is done. It starts when DISC SKIP is pushed again after selection. It is
reset with STOP. (To cancel Mecha Test mode, disconnect the power plug from the outlet.)
29:Mecha
The bridge test of Mecha SW and Mecha Motor is done.
30:FL Check
FL indication check is done. It changes with the DISC SKIP key. It is returned with the STOP key.
31:Shipment
Factory reset. The tray opens. When it is pushed, it closes, and any memory is erased.
32:Soft Ver.
The software version is indicated for three seconds.
•
Error Messages List
Error No.
Status
Contents
E-10
PLAY
CD fails in the disc data reading after the state shift.
E-20
SCAN
E-30
PAUSE
E-70
SEARCH
E-11
PLAY
CD fails in the disc data reading.
E-21
SCAN
E-31
PAUSE
E-73
LOAD
CD fails in the TOC data reading.
E-04
LOAD, SEARCH
Tracking servo is not effective at the DISC MOTOR SERVO PLL.
E-14
LOAD, SEARCH
Disc motor servo PLL is not effective.
E-35
CD fails in FOCUS SEARCH.
E-06
SEARCH, PLAY, PAUSE
CD fails in escaping from the LEAD-IN area.
E-47
SEARCH
The inner limit switch does not operate at the FEED INNER CONTROL.
E-57
STOP
E-77
LOAD, EJECT
E-18
PLAY
CD fails in recovery from the FOCUS OUT.
E-28
SCAN
E-38
PAUSE
E-48
SEARCH
E-68
LOAD
Содержание CRX-E500
Страница 5: ...CDC E500 CDC E500 5 REAR PANELS U C models A model ...
Страница 23: ...CDC E500 CDC E500 23 TIMING CHART ...