2. The current progress will be displayed on the display during the installation as below. 

 

"0 00" 

Checking on the installed data. 

 

"2.CL" 

Deleting the ProgramFlash (Program Area #1) 

 

"2.xx" 

Writing on the Program #1. "xx" indicates percentages. 

 

"3.CL" 

Deleting the ProgramFlash (Program Area #2) 

 

"3.xx" 

Writing on the Program #2. "xx" indicates percentages. 

 

"4.CL" 

Deleting the ProgramFlash (Program Area #3) 

 

"4.xx" 

Writing on the Program #3. "xx" indicates percentages. 

 

 

3. When the installation is completed, “END” will appear. 

 

 

 

 
 

 

4. Remove the USB-Device. 

 

5. Turn off the power switch on the instrument. 

 

 

Confirming the version number 

1)  Turn on the power of the instrument. 

2)  Use the [TEMPO/FUNCTION

] buttons to select Function. 

 

*For CLP-370/340 ; Select Function [F9.4]. 

 

*For CLP-S308/S306 ; Select Function [F8.4]. 

3)  Press the [+ / YES] button to call up the version number. 

4)  Check that the version number is correct for the upgrade, and turn off the power of the 

instrument. 

 

 

Troubleshooting 

☆ 

The power supply was cut off or the USB flash memory was removed during operation. 

- A complete reinstall is necessary. Perform the operation again from the beginning.

 

 

  ☆

 

“InS” is blinking when the power is turn on. 

   

   

- The USB flash memory is not inserted. 

 

   

☆ 

Error number (E.xx) appears and the installation cannot be executed. 

Check the following: 

  ✓

 

Is the USB flash memory inserted correctly?

 

  ✓

 

Is the USB connector free from dust or dirt?

 

  ✓

 

Is the USB flash memory or the upgrade data itself damaged in some way?

 

Try installing it again by using another USB flash memory. 