2. The current progress will be displayed on the display during the installation as below.
"0 00"
Checking on the installed data.
"2.CL"
Deleting the ProgramFlash (Program Area #1)
"2.xx"
Writing on the Program #1. "xx" indicates percentages.
"3.CL"
Deleting the ProgramFlash (Program Area #2)
"3.xx"
Writing on the Program #2. "xx" indicates percentages.
"4.CL"
Deleting the ProgramFlash (Program Area #3)
"4.xx"
Writing on the Program #3. "xx" indicates percentages.
3. When the installation is completed, “END” will appear.
4. Remove the USB-Device.
5. Turn off the power switch on the instrument.
Confirming the version number
1) Turn on the power of the instrument.
2) Use the [TEMPO/FUNCTION
▼
,
▲
] buttons to select Function.
*For CLP-370/340 ; Select Function [F9.4].
*For CLP-S308/S306 ; Select Function [F8.4].
3) Press the [+ / YES] button to call up the version number.
4) Check that the version number is correct for the upgrade, and turn off the power of the
instrument.
Troubleshooting
☆
The power supply was cut off or the USB flash memory was removed during operation.
- A complete reinstall is necessary. Perform the operation again from the beginning.
☆
“InS” is blinking when the power is turn on.
- The USB flash memory is not inserted.
☆
Error number (E.xx) appears and the installation cannot be executed.
Check the following:
✓
Is the USB flash memory inserted correctly?
✓
Is the USB connector free from dust or dirt?
✓
Is the USB flash memory or the upgrade data itself damaged in some way?
Try installing it again by using another USB flash memory.