CDC-697
21
CDC-697
(Note 1) At the SMCK/FCLK pin, output does not stop while /RST=L.
Pin no.
Name
Function
I/O
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
AVSS2
EFM
PCK/
RESY
FLAG
CRC
XSEL
VSS
X1
X2
VDD
VCOF2
AVSS1
OUT1C
OUT1D
OUT2D
OUT2C
AVDD1
DEMPO
CK384
IOSEL
TEST
SBCK2
SUBC
SBCK
CLDCK
IPFLAG
DEMPI
/TEST2
SDATI
LRCKI
BCKI
I
O
O
O
O
I
I
I
O
I
O
O
O
O
O
O
I
O
O
I
I
I
O
I
O
O
I
I
I
I
GND for analog circuit (for AD of DSL, PLL, DA output blocks)
(GND)
EFM signal output
(NC)
With command defaulted: PLL extract clock output PCK when IOSEL=H, frame re-
synchronous signal RESY when IOSEL=L
These settings can be reversed by command (RESY when IOSEL=H).
(NC)
Flag signal output
(NC)
Sub-code CRC check result output (H: OK, L: NG)
(NC)
L: Normal mode
(GND)
H: • For internal master clock, VCO2 output clock for jitter adsorbing PLL is used
instead of Xtal oscillation output (X2).
• VCO2 is always fixed to oscillation mode regardless of VCO2 oscillation stop
command or resetting (/RST=L) and Xtal oscillation is stopped.
GND for oscillation circuit
Crystal oscillation circuit input terminal
Crystal oscillation circuit output terminal
Power supply for oscillation circuit
(+5)
PLL loop filter terminal for jitter adsorption
(GND)
GND for audio DAC
PEM output terminal 1C
(NC)
PEM output terminal 1D
(NC)
PEM output terminal 2D
(NC)
PEM output terminal 2C
(NC)
Power supply terminal for audio DAC
De-emphasis detect signal output
384fs clock output (At the CK384 pin, output does not stop while /RST=L.)
Xtal system when command is defaulted. Signal processing system when command
is switched
(NC)
Mode selecting terminal
(+5)
Test mode setting terminal (Normal: H)
(+5)
Sub-code data read clock input
Sub-code serial output (SBCK effective) when command is defaulted.
PACK data usable (SBCK2 effective) when command is switched
Clock input for sub-code serial output (with pull-up resistor)
(NC)
Sub-code frame clock signal output when command is defaulted (fCLDCK=7.35kHz)
PACK synchronous signal when command is switched
Interpolation flag signal output (H: INTERPOLATION)
(NC)
When IOSEL=H, L: NORMAL H: TEST2
(GND)
Emphasis control in accordance with DEMP0
When IOSEL=L, external DEMP1 input terminal
For emphasis control, DEMP0, OR of DEMP1, DEMP1, forced OFF or forced ON is
selected by command.
When command is defaulted, DEMP0 and OR of DEMP1
SRDATA input (effective only when IOSEL=L)
(NC)
LRCK input (effective only when IOSEL=L) H: Lch data, L: Rch data
(NC)
BCK input (effective only when IOSEL=L)
(NC)
Содержание CDC-697
Страница 5: ...CDC 697 5 CDC 697 REAR PANELS CDC 697 U C models CDC 697 R model CDC 697 T model CDC 697 A model ...
Страница 6: ...CDC 697 CDC 697 6 CDC 697 B G models CDC 697 L model REMOTE CONTROL PANEL ...
Страница 15: ...CDC 697 15 CDC 697 Note 2 Checks FL display DIMMER TEXT TIME ...
Страница 34: ...CDC 697 34 MEMO MEMO MEMO MEMO ...