13
En
ADDITIONAL
IN
FO
RMATION
Engli
s
h
ADDITIONAL INFORMATION
Refer to the chart below if this unit does not function properly. If the problem you are experiencing is not listed below or
if the instructions below do not help, turn off this unit, disconnect the power cable, and contact the nearest authorized
Yamaha dealer or service center.
■
General
TROUBLESHOOTING
Problems
Possible Causes
Solutions
Refer to
page
This unit is not turned
on. The POWER on
indicator also does
not light up.
The power cable is not connected.
Connect the power cable firmly.
The
A
button is pressed on the remote
control while this unit is turned off.
Press
A
switch on the front panel to ON.
There is a problem with the internal
circuitries of this unit.
Disconnect the power cable and contact the nearest
authorized Yamaha dealer or service center. If an
unusual odor or noise is generated from the unit, do
not turn on the power, disconnect the power cable,
and contact a service center for repair.
—
This unit turns off
suddenly and the
POWER on indicator
blinks.
This unit is turned off
after several seconds
of turning on, and the
POWER on indicator
blinks.
The speaker wires are touching each other
or shorting out against the rear panel.
Connect the speaker cables properly and press the
A
switch again. The INPUT indicators blink and the
volume is decreased automatically. After the volume
has decreased to the lowest setting, the INPUT
indicators stop flashing, the INPUT indicator of the
last input source selected lights up, and the unit may
be used again. Confirm normal sound output from
speakers by increasing the volume gradually, then
operate this unit normally.
The speaker is malfunctioning.
Replace the speaker set and press the
A
switch again.
The INPUT indicators blink and the volume is
decreased automatically. After the volume has
decreased to the lowest setting, the INPUT indicators
stop flashing, the INPUT indicator of the last input
source selected lights up, and the unit may be used
again. Confirm normal sound output from speakers
by increasing the volume gradually, then operate this
unit normally.
—
The protection circuitry has been activated
because of excessive input or excessive
volume level.
Rotate the VOLUME control on the front panel to
decrease the volume level and then turn the power on
again.
—
The protection circuitry has been activated
due to excessive internal temperature.
Allow about 30 minutes for the temperature inside
this unit to decrease, rotate the VOLUME control on
the front panel to lower the volume and then turn the
power on again. Set the unit in a place where heat can
readily dissipate from the unit.
—
The IMPEDANCE SELECTOR switch is
not fully slid to either position.
Turn the power off and slide the IMPEDANCE
SELECTOR switch all the way to the correct
position.
The IMPEDANCE SELECTOR switch is
not set to the correct position.
Set the IMPEDANCE SELECTOR switch to the
position that corresponds to the impedance of your
speakers.
This unit has been exposed to a strong
external electric shock (such as lightning
or strong static electricity).
Set this unit to standby mode, disconnect the power
cable, plug it back in after 30 seconds, then use the
unit normally.
—
There is a problem with the internal
circuitries of this unit.
Disconnect the power cable and contact the nearest
authorized Yamaha dealer or service center. If an
unusual odor or noise is generated from the unit, do
not turn on the power, disconnect the power cable,
and contact a service center for repair.
—