3-28
ELECTRICAL
3. Remove:
•
Battery band
•
Battery
4. Measure:
•
Battery charge
Measurement steps:
a. Connect a pocket tester "1" to the
battery terminals.
•
The charge state of an MF battery
can be checked by measuring its
open-circuit voltage (i.e., the volt-
age when the positive terminal is
disconnected).
•
No charging is necessary when the
opencircuit voltage equals or ex-
ceeds 12.8 V.
b. Check the charge of the battery,
as shown in the charts and the fol-
lowing example.
Example
Open-circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge of the battery = 20–30%
A. Relationship between the
open-circuit voltage and the
charging time at 20 °C (68 °F)
(These values vary with the
temperature, the condition of
the battery plates, and the
electrolyte level.)
B. Open-circuit voltage
C. Charging time (hours)
D. Time (minutes)
E. Charging condition of the bat-
tery
F. Ambient temperature 20 °C
(68 °F)
a. Charging
b. Check the open-circuit volt-
age
5. Charge:
•
Battery
(refer to the appropriate charging
method illustration)
Do not quick charge a battery.
•
Never remove the MF battery
sealing caps.
•
Do not use a high-rate battery
charger since it forces a high-
amperage current into the bat-
tery quickly and can cause bat-
tery overheating and battery
plate damage.
•
If it is impossible to regulate the
charging current on the battery
charger, be careful not to over-
charge the battery.
•
When charging a battery, be sure
to remove it from the machine. (If
charging has to be done with the
battery mounted on the machine,
disconnect the negative battery
lead from the battery terminal.)
•
To reduce the chance of sparks,
do not plug in the battery charger
until the battery charger leads
are connected to the battery.
•
Before removing the battery
charger lead clips from the bat-
tery terminals, be sure to turn off
the battery charger.
•
Make sure the battery charger
lead clips are in full contact with
the battery terminal and that they
are not shorted. A corroded bat-
tery charger lead clip may gener-
ate heat in the contact area and a
weak clip spring may cause
sparks.
•
If the battery becomes hot to the
touch at any time during the
charging process, disconnect
the battery charger and let the
battery cool before reconnecting
it. Hot batteries can explode!
•
As shown in the following illus-
tration, the open-circuit voltage
of an MF battery stabilizes about
30 minutes after charging has
been completed. Therefore, wait
30 minutes after charging is com-
pleted before measuring the
open-circuit voltage.
Tester positive probe
→
battery
positive terminal
Tester negative probe
→
battery
negative terminal
Содержание 2008 WR450F
Страница 2: ......
Страница 43: ...2 18 TIGHTENING TORQUES ...
Страница 45: ...2 20 LUBRICATION DIAGRAMS 1 Intake camshaft 2 Exhaust camshaft A To main axle B From oil pump ...
Страница 69: ...3 16 ENGINE INTAKE EXHAUST ...
Страница 82: ...3 29 ELECTRICAL Charging method using a variable voltage charger ...
Страница 83: ...3 30 ELECTRICAL Charging method using a constant voltage charger ...
Страница 96: ...5 2 RADIATOR 11 Pipe 1 O ring 1 1 12 Catch tank breather hose 1 13 Catch tank 1 Order Part name Q ty Remarks ...
Страница 114: ...5 20 CYLINDER HEAD 3 Install Bolt cylinder head 1 Bolt cylinder head 10 Nm 1 0 m kg 7 2 ft lb ...
Страница 133: ...5 39 OIL PUMP 15 Oil pump drive shaft 1 16 Rotor housing 1 Order Part name Q ty Remarks ...
Страница 197: ...6 40 REAR SHOCK ABSORBER 8 Install Plastic band Taillight coupler Locking tie ...
Страница 205: ...7 8 ELECTRIC STARTING SYSTEM 2 Inspect Rubber part a Tears damage Replace ...
Страница 209: ...7 12 ELECTRIC STARTING SYSTEM 5 Install Bolt 1 O ring 2 Apply the lithium soap base grease on the O ring ...