R
ef
er
ences
MIDI Data Format
DME64N/DME24N Owner’s Manual
68
4.1 Program Change (Cnh)
Receive
When the “Program Change Rx Switch” is on, Program Change messages are received on the MIDI
channel specified by the “MIDI Rx Channel” parameter.
If the “Program Change Omni Switch” is also on, however, Program Change messages will be received on
all MIDI channels regardless of the “MIDI Rx Channel” setting.
When a Program Change message is received, the scene assigned to the received program number in the
“MIDI Program Change table” is recalled.
The accepted Bank Select, Program Change range is as follows:
Bank Select MSB: 0
Bank Select LSB: 0 ~ 7
Program Change No.: 0 ~ 127
Transmit
When the “Program Change Tx Switch” is on, the corresponding Program Change number will be
transmitted as specified by the “MIDI Program Change table” and “MIDI Tx Channel” settings.
If multiple Program Change numbers are assigned to a single scene, the Bank Select MSB/LSB and
Program Change number corresponding to the lowest number will be transmitted.
Bank Select MSB
Bank Select LSB
Program Change No.
4.2 Active Sensing (FEh)
Receive
MIDI communication will be initialized if no data is received within 300 ms after reception (Running Status,
etc., will be cleared).
Active Sensing
4.3 Control Change (Bnh)
Receive
When the “Control Change Rx Switch” is on, Control Change messages are received on the MIDI channel
specified by the “MIDI Rx Channel” parameter.
If the “Control Change Omni Switch” is also on, however, Control Change messages will be received on all
MIDI channels regardless of the “MIDI Rx Channel” setting.
Control Change parameter resolution is 128 regardless of the parameters effective range. For finer settings
use Parameter Change.
Transmit
When the “Control Change Tx Switch” is on, appropriate Control Change data will be transmitted when a
parameter is edited via the panel controls, as specified by the “MIDI Control Change table” and “MIDI Tx
Channel” settings.
Transmission does not occur when switching Configurations.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single
parameter.
4.4 Parameter Change (F0h ~ F7h)
Receive
When the “Parameter Change Rx Switch” is On, Parameter Change messages are received on the MIDI
channel specified by the “Device ID (Rx Ch)” parameter.
Status
Bnh (1101nnnnb)
Control Change
Data
00h (00000000b)
Control Change No. 0 (Bank Select MSB)
Data
nnh (0nnnnnnnb)
Control Value (Bank Select MSB No.)
Status
Bnh (1101nnnnb)
Control Change
Data
20h (00100000b)
Control Change No. 32 (Bank Select LSB)
nnh (0nnnnnnnb)
Control Value (Bank Select LSB No.)
Status
Cnh (1100nnnnb)
Program Change
Data
nnh (0nnnnnnnb)
Program Change No. (0-127)
Status
FEh (11111110b)
Active Sensing
Status
Bnh (1011nnnnb)
Control Change
Data
cch (0cccccccb)
Control Change No. (1-31,33-95,102-119)
vvh (0vvvvvvvb)
Control Value (0-127)
Содержание 1009MWTO-F0
Страница 1: ...EN Owner s Manual DIGITAL MIXING ENGINE ...
Страница 76: ...DME64N 24N Owner s Manual 76 MEMO ...
Страница 77: ...DME64N 24N Owner s Manual 77 MEMO ...
Страница 78: ...DME64N 24N Owner s Manual 78 MEMO ...