11
PROBLEM
POSSIBLE CAUSE
REMEDY
Compressor is off.
Turn on compressor.
Valve on air piping is closed.
Open valve.
Air pressure setting is under 0.2MPa.
Set air pressure to 0.2MPa or above.
Valve on material outlet is closed.
Open valve.
Frost occurs inside silencer.
Use dry air.
O ring on sliding part of air piston is worn out.
(Air leak occurs from silencer.)
Block (773210) and ball (686271) in valve body (804815) are
worn out.
Any parts (e.g. spring, pin) used in switching system in valve
body (804815) or air motor (804814 / 804856) are damaged.
Air leak from air
motor
- Fasteners are loose.
- O rings and packings are worn out.
- Retighten loose parts.
- Replace worn part.
Air leak from
silencer during
shutdown
- Foreign object is caught between block (773210) and
valve seat (716246) in valve body (804815).
- Seating part is worn out.
- Remove foreign object.
- Replace worn part.
Pump doesn’t run
and air leaks from
silencer
- Foreign object is caught between spindle (716299) and
valve switcher (832996) in air motor (804814 / 804856).
- There exists damage that prevents sliding movement of
parts below.
- Remove foreign object.
- Replace damaged part.
Pump doesn’t draw
material at first time
of operation
Pump operating speed is so fast that lower pump suction
cannot keep up with pump movement. (Valve inside lower pump
is not working well.)
Set pump speed to 5-8 sec. per cycle
until material is pumped out.
If upward movement of plunger is faster,
- seat surface of piston valve is defective (wear of seat
surface, inclusion of foreign material) or,
- packings are damaged.
If downward movement of plunger is faster,
- seat surface of foot valve is defective (wear of seat
surface, inclusion of foreign material),
- packings are damaged, or
- shovel rod is bent.
If downward movement of plunger is faster, operating speed is
so fast that lower
pump suction cannot keep up with pump movement. (Vacuum
is caused inside lower pump.)
Decrease air pressure until material
comes out. (This pressure is the upper
limit of normal operating pressure.)
Connecting rod connecting air motor and lower pump is
completely separated from air motor. (In this case, parts inside
of lower pump may be damaged.)
Inspect inside lower pump first, then
replace damaged part, and retighten
each part.
Leak occurs in delivery pipe.
Leak occurs in lower pump (connections are loosened or o ring,
backup ring, or packing is damaged).
Material leak from
lower pump
- Fasteners are loose.
- O ring, backup ring or packing is damaged.
- Retighten loosened parts.
- Replace damaged part.
Material contains
air bubbles even
after bleeding
- Fasteners are loosened.
- O ring or backup ring is damaged.
- Retighten loosened parts.
- Replace damaged part.
- Retighten loose parts.
- Replace damaged part.
Pump doesn’t stop
- Remove foreign object.
- Replace damaged part.
Pump doesn’t run
Replace worn out or damaged part.
Material cannot be
pumped out
5.2 Troubleshooting
If you suspect that you have a problem with your product, consult the table below for some common problems and
their solutions. Contact the retail store where you purchased your product or our business office if all else fails.
Содержание SH-125B Series
Страница 29: ......