background image

19 

7. Specifications 

Specifications

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SH-125B3.5

DR-125B3.5

SH-125B5

DR-125B5

SH-125B13

DR-125B13

854592

854593

854594

854595

854596

854597

Suction port

R 1-1/2

Discharge
Port

Air
Connection

Supply Port

 A-weighted
Sound
Pressure
Level*

1

A-weighted
Sound Power
Level*

2

Env.
Temperature
Material
Temperature

28.9 kg

30.5 kg

27.3 kg

28.9 kg

22.6 kg

26.0 kg

SH-125B3.5-V DR-125B3.5-V SH-125B5-V

DR-125B5-V

SH-125B13-V DR-125B13-V

854598

854599

854600

854601

854602

854603

Suction port

R 1-1/2

Discharge
Port

Air
Connection

Supply Port

 A-weighted
Sound
Pressure
Level*

1

A-weighted
Sound Power
Level*

2

Env.
Temperature
Material
Temperature

28.9 kg

30.5 kg

27.2 kg

28.8 kg

22.6 kg

26.0 kg

    

*1 Measurement method of A-weighted sound pressure level is based on ISO 1996.

    

*2 Measurement method of A-weighted sound power level is based on ISO 3744.

    

*3 Discharge volume (per cycle) varies according to use conditions.

13 ×1

Rc 1-1/2

Rc 1

Rc 3/4

3.5 MPa

0.2 ~ 0.7 MPa

83.8 dB

9.1 MPa

78.4 dB

88.4 dB

Maximum Discharge
Pressure

2.45 MPa

3.5 ×1

5 ×1

619 mL

92.2 dB

0 ~ 60 

0 ~ 80 

100 mm

Discharge Volume per
Cycle *

3

Maximum
operating
noise

Amb.
Temp.
Range

Stroke(Nominal)

171 mL

Type
Model No.
Pump Ratio (Nominal)

Operating Air Pressure

88.4 dB

458 mL

Material
Connection

Rc 3/8

Rc 1-1/2

Type
Model No.

13 ×1

5 ×1

Weight

Maximum
operating
noise

92.2 dB

Rc 3/4

3.5 MPa

9.1 MPa

Rc 3/8

83.8 dB

78.4 dB

0 ~ 60 

0 ~ 80 

458 mL

171 mL

Weight

Maximum Discharge
Pressure

2.45 MPa

Stroke(Nominal)
Discharge Volume per
Cycle *

3

619 mL

Amb.
Temp.
Range

100 mm

Pump Ratio (Nominal)

3.5 ×1

Material
Connection

Rc 1

Operating Air Pressure

0.2 ~ 0.7 MPa

Содержание SH-125B Series

Страница 1: ...854593 854595 854597 DRUM TYPE SH 125B V MODEL No 854598 854600 854602 SIPHON TYPE V DR 125B V MODEL No 854599 854601 854603 DRUM TYPE V WARNING Prior to operating this pump be sure to read this opera...

Страница 2: ...Cautions For safe use of this product be sure to note the following In this document warnings and cautions are indicated by symbols These symbols are for those who will operate this product and for t...

Страница 3: ...ating and disassembling the pump Ground connection Make ground connection to pump and peripheral equipment Rapid pumping of material can result in static electrical charge Also be sure to provide prop...

Страница 4: ...art until the cause has been identified and corrected Shut off air supply Shut off the air source before installation and piping Install properly Install the unit properly according to the requirement...

Страница 5: ...vention measures Take fall prevention measures if using a slim or light tank Risk of falling will be increased due to shift in center of gravity caused by change in the material level in a tank When u...

Страница 6: ...mp 4 3 5 Installation of silencer 4 3 6 Connecting the ground wire 4 3 7 Discharge piping 5 3 8 Air piping 5 3 9 Preparation for use 5 4 Operating Method 6 4 1 Operation switch and valve 7 4 2 Solvent...

Страница 7: ...up material When compressed air generated by the compressor is fed into the air motor the air switching mechanism built in the air piston actuates vertical reciprocating motions The connecting rod joi...

Страница 8: ...rmality discontinue pump operation and refer to Troubleshooting to solve the problem Shut off the air source before installation and piping When installing the pump select an appropriate place and sui...

Страница 9: ...drum pump Using a bung adapter DR 125B13 1 Remove a plug on a drum and attach a bung adapter sold separately 2 Insert the pump into the bung adapter Once the lower end foot valve reaches the bottom of...

Страница 10: ...tape around the silencer thread to prevent leakage 3 6 Connecting the ground wire WARNING Make ground connection when working with flammable material or in explosive atmosphere Rapid pumping of materi...

Страница 11: ...ipe somewhere accessible between the air source and unit 2 Select an air supply hose fitting and air equipment that satisfy the following requirements With these devices connect an air piping and the...

Страница 12: ...in personal injury or property damage Be sure to use the unit in accordance with the specifications in this manual Always wear proper safety equipments facemask ear plugs and safety shoes etc when in...

Страница 13: ...rom falling over hang the pump with a crane etc or fix container firmly DR type only Material remaining inside or on the surface of the pump may spill out by inserting or removing the pump into from a...

Страница 14: ...opriate pressure for each season 4 5 Retightening gland packing V series Because of the deformation or wear of gland packing solvent cup of V series loose the tightness In order to protect plunger and...

Страница 15: ...ation immediately when a drum becomes empty Running the pump dry will cause excessive Be especially careful when pumping explosive material Mixture of an air and vaporized material can explode If ther...

Страница 16: ...e for the pump and set the pump air regulator knob to 0MPa Without a lubricator Disconnect the air piping from the air inlet of the pump and apply a few drops approx 0 5mL of lubricant directly to the...

Страница 17: ...lve is defective wear of seat surface inclusion of foreign material or packings are damaged If downward movement of plunger is faster seat surface of foot valve is defective wear of seat surface inclu...

Страница 18: ...6 million cycles 854596 854602 854597 854603 SH 125B13 SH 125B13 V DR 125B13 DR 125B13 V 804859 804863 804860 804864 Plunger 1 per unit 10 million cycles 685795 685795 Packing 1 per unit 5 million cy...

Страница 19: ...54600 1 804855 Air motor assembly 1 4 632059 Slit pin 1 5 716409 Bushing 1 6 700350 Cap nut 1 7 716410 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804857 804858 804861 804862 Nut 1 14 80469...

Страница 20: ...1 7 716411 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804857 804858 804861 804862 Lower pump assembly 1 12 716288 Joint 1 13 716412 Connecting rod 1 14 804697 Silencer 1 No Part No Descrip...

Страница 21: ...Packing 1 10 14 701381 701371 Washer 1 10 15 716413 Stud 1 10 16 716425 716427 Plunger 1 10 17 701382 701369 Cylinder 1 10 18 704742 704744 Chamber 1 10 19 630479 Ball 1 10 21 770493 770208 Packing 2...

Страница 22: ...Packing gland 1 10 14 701381 701371 Washer 1 10 15 716413 Stud 1 10 16 716425 716427 Plunger 1 10 17 701382 701369 Cylinder 1 10 18 704742 704744 chamber 1 10 19 630479 Ball 1 10 21 770493 770208 Pack...

Страница 23: ...2 704583 704580 Cylinder Suction tube 1 10 13 640012 O ring 1 10 14 632774 Spring pin 1 10 15 627016 Nut 1 10 16 701554 Housing 1 10 17 630334 Ball 1 10 18 701553 Valve seat 1 10 19 770233 Revolving s...

Страница 24: ...716433 rod 1 10 12 704583 704580 Cylinder Suction tube 1 10 13 640012 O ring 1 10 14 632774 Spring pin 1 10 15 627016 Nut 1 10 16 701554 Housing 1 10 17 630334 Ball 1 10 18 701553 Valve seat 1 10 19 7...

Страница 25: ...t method of A weighted sound pressure level is based on ISO 1996 2 Measurement method of A weighted sound power level is based on ISO 3744 3 Discharge volume per cycle varies according to use conditio...

Страница 26: ...20 Dimensions DR 125B3 5 5 SH 125B3 5 5 DR 125B13 SH 125B13 Part No A mm B mm 854592 854594 854598 854600 854593 854595 854599 854601 854596 854602 854597 854603 660 1314 1769 1058 600 1298 840 1115...

Страница 27: ...nce curve NOTE Avoid continuous operation if a desired discharge volume is in the shaded area in the right side of each figure SH DR 125B3 5 SH DR 125B3 5 V SH DR 125B5 SH DR 125B5 V SH DR 125B13 SH D...

Страница 28: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Страница 29: ......

Страница 30: ...201810 APP079U Manufactured by YAMADA CORPORATION INTERNATIONAL DEPARTMENT No 1 3 1 Chome Minami Magome Ohta ku Tokyo 143 8504 Japan PHONE 81 0 3 3777 0241 FAX 81 0 3 3777 0584...

Отзывы: