9
3.4 Replacement of pail
CAUTION
-
Do not try to separate the inductor plate from a pail at once with the “PRESS” button depressed.
Compressed air built up inside a pail may be released causing a spurt of residual material.
1
)
When a pail becomes empty, the pump will run dry and NOT stop automatically. Close the pump air valve and
adjust air pressure to 0MPa using the pump air regulator.
2
)
Set the lift control switch to “UP” to raise the lift to the upper limit.
3
)
Press the “AIR” button a few times to allow air to flow between the inductor plate and a pail. A pail will be
gradually separated from the inductor plate by rotating it. When a pail is hard to remove, push the “AIR” button
several times again and then rotate a pail slowly to separate it from the inductor plate.
4
)
Once the inductor plate is separated from a pail, set a new pail according to the procedure described in “3.2
Placement of pail”.
3.5 After work
CAUTION
-
After work or when shutting down the unit for a long period, be sure to turn off the air supply source
to disconnect air supply to the pump, and open the valves on the material outlet or gun to release
residual pressure inside the pump and piping. Failure to shut off air may cause damage to the hoses
and pipes and/or leak in the valves and gun. Any secondary accidents caused by the failure
mentioned above are the responsibility of the users.
1
)
Close the air valve for the pump and set the pump air regulator to 0MPa.
2
)
Set the lift control switch to “DOWN”.
<NOTE>
[Air release plug on inductor plate]
- When using the “air release plug” for the first time, it should be positioned on the upper side to release air more
efficiently.
- It’s recommended that if there is no residual material inside the inductor plate, when replacing a pail, position
the “air release plug” on the upper side and release air. Also if material is left inside the inductor plate, switch
the position of the “air release plug” and the “plug” to release air from the lower hole. However, this may not be
applied to some materials or situations.
[Filter on inductor plate (flat packing type)]
- In the flat packing type, a punch plate is attached on the bottom of the inductor plate to make it possible to use
up material in a pail as much as possible.