Yale Z-Wave Plus Product Info ................................................................................................................. 3
Supported Command Classes .................................................................................................................. 3
Association Table .................................................................................................................................... 4
Notifications Table .................................................................................................................................. 4
Configurable Parameters ......................................................................................................................... 6
Страница 1: ...If you re adding a new Yale Smart Module follow the instructions included with it P N AYR202 ZW INSTAL FUL Rev E Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install...
Страница 2: ...tion is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the...
Страница 3: ...ior Escutcheon 5 After entering the Master PIN code press any key to complete handing Press Enter new Master PIN code 4 8 digits Press to complete FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN...
Страница 4: ...the latch during Automatic Re lock duration or when Automatic Re lock is disabled Shutdown Time The unit will shutdown ashing keypad for sixty 60 seconds and not allow operation after the wrong code e...
Страница 5: ...1 Yale Locks YRD116 126 136 156 Z Wave Plus System Integrators Guide Yale Assure Deadbolt Lock June 3 2019...
Страница 6: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 4 Notifications Table 4 Configurable Parameters 6...
Страница 7: ...Wave Plus Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery Command Class Door L...
Страница 8: ...evel user slot number Tamper Alarm 0xA1 0x01 keypad attempts exceed code entry limit 0x02 front escutcheon removed from main RF Operate Unlock 0x19 0x01 by RF module Manual Unlock 0x16 0x01 By key cyl...
Страница 9: ...users A valid user can be both a normal user and a Non Access user If a non access user is out of schedule this alarm will be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0...
Страница 10: ...default is 30 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds Operating mode 8 1 byte 00 nor...