Yale Z-Wave Plus YRMZW2-US Скачать руководство пользователя страница 3

Rotate

P/N YRD136-MNL-0008 Rev A

2-3/8" position

2-3/4" position

O

optional

x4

Installing Latch & Strike Plate

1

Bolt must be in retracted 

(unlocked) position. UP 

arrow must be facing 

upwards.

!

Installing Keypad Escutcheon

2

Outside of Door

Ensure cable is 

routed under the 

deadbolt. 

!

Installing Interior Mounting Plate

3

Attaching the Cable Assembly

4

Testing Operation

Preparing Door and 
Keypad Escutcheon

Initial Programming

Bolt must be in 

retracted 

(unlocked) 

position before 

installing AA 

batteries.

!

6

Yale  ProSL 

®

Key Free Keypad Deadbolt with Z-Wave Plus

Installation and Programming Instructions

Installing Cover

®

Congratulations, you've installed the Yale  ProSL Key Free 

Keypad Deadbolt with Z-Wave Plus!  Turn sheet over for 

Programming Instructions to customize your product.

default

Installing Interior Escutcheon

5

After entering the Master PIN

code, press any key to complete

handing.

Press    . 
Enter new Master PIN
code (4-8 digits). 
Press     to complete.

®

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO

THE PRODUCT AND VOID THE FACTORY WARRANTY

Before you begin

for step-by-step installation

instructions & to register

your product

DOWNLOAD

THE BILT APP

3

2- /

8

3

2- /

8

3

2- /

4

Thumbturn 

should be in 

vertical 

position.

!

Deadbolt should 

extend and retract 

smoothly. If not, go 

back to step 2.

!

Lock will not operate 

until gear is pressed 

and Master PIN code 

is set.

!

x4

x3

#8-32 x 5/16"

Machine screws

#7 wood & #8-32

machine x 20mm

Combination screws 

x2 Silver

M6x55mm

PPHMS
(2-1/4")

OR

x2 Black

M6x44mm

PPHMS

(Standard 1-3/4" - 2") 

OR

x2 Gold

M6x36mm

PPHMS
(1-3/8") 

x2

Choose 

through bolt 

appropriate for 

your door 

thickness. 

!

If bore hole is less 

than 2-1/8", remove 

cup by gently 

compressing two 

tabs while pulling.

!

!

Cup must be removed from 

escutcheon if bore hole is 

less than 2-1/8".

2-1/8" Application

<2-1/8" Application

Содержание Z-Wave Plus YRMZW2-US

Страница 1: ...If you re adding a new Yale Smart Module follow the instructions included with it P N AYR202 ZW INSTAL FUL Rev E Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install...

Страница 2: ...tion is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the...

Страница 3: ...ior Escutcheon 5 After entering the Master PIN code press any key to complete handing Press Enter new Master PIN code 4 8 digits Press to complete FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN...

Страница 4: ...the latch during Automatic Re lock duration or when Automatic Re lock is disabled Shutdown Time The unit will shutdown ashing keypad for sixty 60 seconds and not allow operation after the wrong code e...

Страница 5: ...1 Yale Locks YRD116 126 136 156 Z Wave Plus System Integrators Guide Yale Assure Deadbolt Lock June 3 2019...

Страница 6: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 4 Notifications Table 4 Configurable Parameters 6...

Страница 7: ...Wave Plus Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery Command Class Door L...

Страница 8: ...evel user slot number Tamper Alarm 0xA1 0x01 keypad attempts exceed code entry limit 0x02 front escutcheon removed from main RF Operate Unlock 0x19 0x01 by RF module Manual Unlock 0x16 0x01 By key cyl...

Страница 9: ...users A valid user can be both a normal user and a Non Access user If a non access user is out of schedule this alarm will be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0...

Страница 10: ...default is 30 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds Operating mode 8 1 byte 00 nor...

Отзывы: