Yale Z-Wave Plus YRMZW2-US Скачать руководство пользователя страница 4

Press   

Press   

Press   

Press each keypad key for response when pressed.

Apply 9V battery to terminals below the keypad for

Programming Instructions

Press   

Enter Master PIN code

Press   

Enter 4-8 digit PIN code

 

"Unlock"

Audio Mode

 All Code Lockout Mode

Enable

Enable

Disable

Disable

For quiet areas, select Disable (3) 

in  Audio Mode.

    Programming Troubleshooting

Symptom

Suggested Action

Press   

Press   

Press   

Press   

Press   

    

Definitions

Changing Master PIN Code

1

Enter 4-8
digit Master
PIN Code. 

Creating User PIN Codes

2

Master PIN code must be created first.
*Max User Codes = 250 in network  

Unlocking Door with PIN Code

3

Enter PIN   
Press   

    Resetting Lock to Factory Default

    Factory Settings

Settings

Factory Setting

Master PIN Code

Registration 

required*

Automatic Re-lock

Disabled

One Touch Locking

Enabled

Audio

Enabled

Automatic Re-lock Time

30 Seconds

Wrong Code Entry Limit

5 Times

Shutdown Time

60 Seconds

*The Master PIN code must be registered prior to any other programming of the lock.

When lock is reset to factory defaults all 
user codes (including the Master PIN 
code*) are deleted and all programming 
features are reset to original default 
settings (see "Factory Default Settings").

2. Remove the batteries.

1. Remove the battery cover.

Upon reset, Master Code creation is the 
only option available and must be 
performed prior to any other 
programming of the lock.

4. Replace battery cover.

NOTE: After setting the Master Code, 
press any key to complete handing of 
the lock.

3. While pressing the reset button 

(minimum of 3 seconds) reinstall 
batteries. Release reset button.

Default settings
in 

bold.

    Enrolling Lock In Z-Wave Plus Network 

Your network controller first needs to be in 
enrollment or exclusion mode for the lock 
to be enrolled or removed from network. 

1. Remove the battery cover.
2. Press    button and hold until unit beeps 

two (2) times.

Once you put the controller in the 
enrollment or exclusion mode, the lock 
can be enrolled or removed in the Z-Wave 
Plus Plus network by pressing the    
button.

3. Release button and network removal 

automatically begins.

To enroll lock using the    button option:

3. Release button and network joining 

automatically begins.

4. Replace battery cover.

1. Remove the battery cover.

4. Replace battery cover.

To remove lock using the    button option:

2. Press    button and hold until unit beeps 

five (5) times.

Product Support Tel 1-855-213-5841 • www.yalehome.com

ASSA ABLOY Residential Group. Other products' brand names may be trademarks or registered

permission of ASSA ABLOY Residential Group is prohibited.

Yale® and Yale Real Living® are registered trademarks of

© Copyright 2019. All rights reserved. Reproduction in whole or in part without the express written

trademarks of their respective owners and are mentioned for reference purposes only.

Master PIN Code must be created before any further programming.
Max User Codes = 250 in network 

Warning: 

Changes or modifications to this device, not expressly approved by 

ASSA ABLOY Residential Group could void the user's authority to operate the 
equipment.

PIN Code Management - Up to 250 Users (in network) 

Duplicate if necessary 

User Name

PIN Code

    Code Chart

Low Battery Warning
Flashes RED

All Code Lockout Mode:

 This feature is enabled by the Master code. When enabled, it 

restricts all user (except Master) PIN code access. When attempting to enter a code while 
the unit is in Lockout, the lock rapidly beeps 5 times.

Audio Mode:

 Choosing 

Disable (3)

 in Audio mode shuts off the code confirmation tone 

play-back for use in quiet areas. Audio mode is enabled or disabled through feature 
programming by the Master code.

Automatic Re-lock Time: 

After a successful code entry or manual unlock with the key, the 

lock will automatically re-lock after each unlock in an effort to keep your home secure. This 
feature is optional, and can be turned off. In the ON mode, the lock will automatically re-lock 
after thirty (30) seconds.

Low Battery:

 When battery power is low, the Low Battery Warning Indicator flashes RED. If 

battery power is completely lost, use the 9Volt battery override. To use the 9V battery 
override apply 9V battery, in either direction, to terminals below the keypad for backup 
power option. Wake up the lock and enter your pin code to unlock the door. 

Master PIN Code:

 The Master PIN code is used for programming and for feature settings. 

It

 

must be created prior to programming the lock.

 The Master code will also operate 

(unlock/lock) the lock.

Network Setting:

 This setting is available through the wireless button on the interior 

escutcheon     and allows the lock to connect with a network controller.  

User PIN Code: 

The User code operates the lock. Maximum number of user codes is 250 in 

network.

Wrong Code Entry Limit: 

After five (5) unsuccessful attempts at entering a valid PIN code, 

the unit will shut down and not allow operation for sixty (60) seconds. 

Tamper Alert:

 Audible alarm sounds if attempting to forcibly remove outside lock from door.

One Touch Locking: 

When the latch is retracted, activating the keypad will extend the latch 

(during Automatic Re-lock duration or when Automatic Re-lock is disabled).

Shutdown Time: 

The unit will shutdown (flashing keypad) for sixty (60) seconds and not 

allow operation after the wrong code entry limit has been met. 

All Code Lockout Mode 
Rapidly beeps 5 times

Failsafe 9 Volt
Battery Connection
(Use Alkaline battery)

®

While Yale  has included several features to prevent lockout (9-
Volt battery jumper, low battery warnings), it is still possible for 
a lockout situation to occur. Because this product does not 

®

have a mechanical override (a key), Yale  recommends to use 
this product in an environment where there are additional 
entry points into the dwelling.

NOTE TO INSTALLER AND CONSUMER

Keypad Wake-Up

M

U

Master PIN Code Setting

  User PIN Code Registration

 Register

Delete

    Complete

Handing the Lock 

Preforms automatic

handing of the lock

Advanced Lock Settings

Automatic Re-lock 

Disable

  30 sec

One Touch Locking 

Enable

  Disable

Continue

  60 sec

  3 min

  2 min

U

  

2. Enter the 4-8 digit Master PIN code followed by the 

 key. 

3. Enter digit corresponding to the function to be performed followed by the 

 key. 

1. Wake the lock by pressing the        . 

!

Warning: 

Changes or modifications to this device, not expressly approved by 

ASSA 

ABLOY Residential Group 

could void the user's authority to operate the equipment.

Industry Canada:

Section 7.1.3 of RSS-GEN

 This Device complies with 

Industry Canada License-exempt RSS standard(s). 
Operation is subject to the following two conditions: 1) 
this device may not cause interference, and 2) this 
device must accept any interference, including 
interference that may cause undesired operation of the 
device.

Contain 11626A- YRIZW2USTS1

Le présent émetteur radio 6982A-YRHCPZW0FM a été 
approuvé par Industrie Canada pour fonctionner avec 
les types d'antenne énumérés ci-dessous et ayant un 
gain admissible maximal. Les types d'antenne non 
inclus dans cette liste, et dont le gain est supérieur au 
gain maximal indiqué, sont strictement interdits pour 
l'exploitation de l'émetteur.

CAN ICES-3B/NMB-3B

Section 7.1.2 of RSS-GEN

 Under Industry Canada 

regulations, this radio transmitter may only operate 
using an antenna of a type and maximum (or lesser) 
gain approved for the transmitter by Industry Canada. 
To reduce potential radio interference to other users, 
the antenna type and its gain should be so chosen that 
the equivalent isotropically radiated power (e.i.r.p.) is 
not more than that necessary for successful 
communication.
En vertu des règlements d'Industrie Canada, cet 
émetteur radio ne peut fonctionner avec une antenne 
d'un type et un maximum (ou moins) approuvés pour 
gagner de l'émetteur par Industrie Canada. Pour 
réduire le risque d'interférence aux autres utilisateurs, 
le type d'antenne et son gain doivent être choisies de 
façon que la puissance isotrope rayonnée équivalente 
(PIRE) ne dépasse pas ce qui est nécessaire pour une 
communication réussie.

Model:  YRD156-ZW-619,605,0BP

This radio transmitter 6982A-YRHCPZW0FM has been 
approved by Industry Canada to operate with the 
antenna types listed below with the maximum 
permissible gain indicated. Antenna types not included 
in this list, having a gain greater than the maximum 
gain indicated for that type, are strictly prohibited for 
use with this device. 

Cet appareil est conforme avec Industrie Canada RSS 
standard exemptes de licence(s). Son fonctionnement 
est soumis aux deux conditions suivantes: 1) ce 
dispositif ne peut causer des interférences, et 2) cet 
appareil doit accepter toute interférence, y compris les 
interférences qui peuvent causer un mauvais 
fonctionnement du dispositif.

Ÿ

 Connect the equipment into an outlet on a circuit 
different from that to which the  receiver is 

connected.

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC 
RULES. OPERATION IS SUBJECT TO THE FOLLOWING 
TWO CONDITIONS.

This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful 
interference in a residential installation. This 
equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there 
is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause 
harmful Interference to radio or television reception, 
which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

FCC:

Contain FCC ID: 2ABFG- YRIZW2USTS1 

Ÿ

 Reorient or relocate the receiving antenna.

Model: YRD156-ZW-619,605,0BP

Ÿ

 Increase the separation between the equipment 
and receiver.

Ÿ

 Consult the dealer or an experienced radio/TV 
technician for help.

(1) THIS DEVICE MAY NOT CAUSE HARMFUL 
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT 
ANY INTERFERENCE RECEIVED, INCLUDING 
INTERFERENCE THAT MAY CAUSE UNDESIRED 
OPERATION.

Enter Master PIN code

Press   

Press   

Press   

Feature Programming Through Menu Mode
Using Master PIN code*

Use this procedure only 

when network primary 

controller is missing or 

otherwise inoperable.

Содержание Z-Wave Plus YRMZW2-US

Страница 1: ...If you re adding a new Yale Smart Module follow the instructions included with it P N AYR202 ZW INSTAL FUL Rev E Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install...

Страница 2: ...tion is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the...

Страница 3: ...ior Escutcheon 5 After entering the Master PIN code press any key to complete handing Press Enter new Master PIN code 4 8 digits Press to complete FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN...

Страница 4: ...the latch during Automatic Re lock duration or when Automatic Re lock is disabled Shutdown Time The unit will shutdown ashing keypad for sixty 60 seconds and not allow operation after the wrong code e...

Страница 5: ...1 Yale Locks YRD116 126 136 156 Z Wave Plus System Integrators Guide Yale Assure Deadbolt Lock June 3 2019...

Страница 6: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 4 Notifications Table 4 Configurable Parameters 6...

Страница 7: ...Wave Plus Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery Command Class Door L...

Страница 8: ...evel user slot number Tamper Alarm 0xA1 0x01 keypad attempts exceed code entry limit 0x02 front escutcheon removed from main RF Operate Unlock 0x19 0x01 by RF module Manual Unlock 0x16 0x01 By key cyl...

Страница 9: ...users A valid user can be both a normal user and a Non Access user If a non access user is out of schedule this alarm will be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0...

Страница 10: ...default is 30 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds Operating mode 8 1 byte 00 nor...

Отзывы: