8
Technical data
09.2019
31
ba
-o
.4
.1
.3
-en
-2
.2
-y
8
Technical data
Supply
Voltage variants
AC voltage:
24 V 50 / 60 Hz
42 V 50 / 60 Hz
48 V 50 / 60 Hz
110/120 V 50 / 60 Hz
230 V 50 / 60 Hz
DC voltage:
24 V DC
Residual ripple:
±5 %
Voltage tolerance
90 … 115
%
Power consumption at rated voltage
9 VA
Fuse protection control current circuit
6.3 A, slow blow
Actuation
Galvanic isolation
Yes
Signal level input inactive
< 40 %
of the supply
Signal level input active
> 70 %
Relay outputs
Control relays
per EN 13849-1, Cat. 2
4
Utilization category
- EN 60947-5-1,
AC15: 250 V / 2
A (inductive load cos φ=0.7), 5
A (resistive load)
DC13: 30 V / 2 A
At +70 °C (optional)
AC15: 250 V / 1.5
A (inductive load cos φ=0.7), 3
A (resistive load)
Signaling relays / Temperature monitoring relay
4, volt-free
Utilization category
- EN 60947-5-1,
AC15: 250 V / 2
A (inductive load cos φ=0.7), 5
A (resistive load)
DC13: 30 V / 2 A
At +70 °C (optional)
AC15: 250 V / 1.5
A (inductive load cos φ=0.7), 3
A (resistive load)
Inputs load sensor
Load sensor type
Passive DMS sensor, full bridge
Supply DMS sensor
+S
10 V DC ± 5 %
-S
0 V DC
Load signal input
+IN
2 mV / V,
350
-IN
Measurement range
0...20 mV
Max. error of measurement at 25 °C referred to the
smallest-possible cut-off point
±3 %
Overload cut-off point
Parameterizable
PTC inputs
Maximum total initial resistance
Max. 1500
(IEC / EN 60947-8)
Pick-up resistance
2800 … 3500
Maximum release resistance:
1650
Environmental conditions
Insulation strength
Clearances and creepage distances per IEC / EN 60664
Rated insulation voltage 250 V AC
Pollution degree 2
Protection class II
Overvoltage categories III
Содержание SLE 3
Страница 2: ...ba o 4 1 3 en 2 2 y...
Страница 4: ...4 09 2019 ba o 4 1 3 en 2 2 y 8 2 Type designation 33...
Страница 35: ...Annex 09 2019 35 ba o 4 1 3 en 2 2 y Notes...