background image

5

Most of the devices are provided with either internal or external security 
tamper mechanism,  please make sure the tamper spring is fully 
compressed when you install the devices.

(05)

Keyfob
AC-KF

Available with IA-230 Kit
or as accessory

Contactless Tag
AC-RFIDTAG

1

5

Содержание IA-210

Страница 1: ...1 Intruder Alarm Kit IA 210 IA 220 IA 230 The smarter way to protect your home Quick Start Guide Full User Manual ...

Страница 2: ...Please visit the registration web page and insert the product details Register your product to get products news and updates if you need extra accessories or spare parts please visit yale co uk 1 Installation Service Want us to install this product Why not call Yale Smart Security Partners and let a professional installer take care of the rest Choose your package online at www yalestore co uk inst...

Страница 3: ... in the following pages See your box for kit content Unpack your kit Plan your system Panel set up Device installation Activating devices Device installation Testing device signal strength Device installation Install the devices in the desired location Using the system Each kit contains different components see your box for kit content Index 3 Page 4 Page 6 Page 7 Page 9 Page 10 Page 11 Page 15 ...

Страница 4: ...ctivate your alarm immediately even when the system is disarmed How to Disarm 3sec Motion Detector Pet AC PETPIR Available with IA 230 Kit or as accessory How to Full Arm How to Part Arm Max 27 kg All the devices in this kit are pre paired for easy installation If you are adding more devices purchased separately to this kit you will need to pair these into the system separately see page 18 1 Unpac...

Страница 5: ...ed with either internal or external security tamper mechanism please make sure the tamper spring is fully compressed when you install the devices 05 Keyfob AC KF Available with IA 230 Kit or as accessory Contactless Tag AC RFIDTAG 1 5 ...

Страница 6: ... not point directly at a source of heat eg fires or boilers facing a window or a door protected by a Door Window contact Avoid installing directly above radiators 4 If you have Pets that may climb on furniture avoid using PET PIR Motion detectors as this can cause false alarms Instead replace with additional Door Window Contacts 5 Mount the External siren as high as possible on an external wall Pl...

Страница 7: ...7 1 2 4 5 07 Standard PSTN phone landline socket The wall mounting holder should be always inserted because the panel has got a tamper switch 3 3 Panel set up O n O ff a b c a b c d 3 Panel Set up 7 ...

Страница 8: ...ons please visit the product page and download the full advanced manual for further details When set up is complete select Exit set up Press to confirm Press PIN code to exit the set up process If you wish to repeat the process select Repeat set up Press to confirm Wecome to your Yale Alarm System Yale Intruder Alarm Initial Menu Exit set up Repeat set up Continue installation www yale co uk Panel...

Страница 9: ... page 18 Device Installation Test device signal 10 PIR Zone03 E T 9 PIR 1 If signal strength is below 2 please try to move the device to a different location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and...

Страница 10: ... location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and press to enter the panel into learning mode Press button to test connection 5 8 9 5 Device Installation Testing Device Signal Strength 10 ...

Страница 11: ...11 1 a b c 1 8m 2 1m d 2 a a b 3 4 5 6 11 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation Install the devices in the desired location 11 ...

Страница 12: ...2 1 3 5 6 7 2 4 a b max 10mm or 12 6 Device installation Install the device in the desired location Clean the mounting surface before application with a suitable degreasing agent 6 Device Installation 12 ...

Страница 13: ...13 13 6 1 3 4 5 2 6 a a a b b b c d Ø 5mm Device installation Install the device in the desired location 13 ...

Страница 14: ...14 1 a a d b b c 2 3 4 5 6 14 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation 14 ...

Страница 15: ... is possible to set an entry delay timer to allow you to enter the property and disarm your system before the alarm is triggered download the advanced manual for full instructions When the alarm is triggered the system will auto dial pre programmed telephone numbers Please download the full user manual to find how to set up more telephone numbers use the telecommunication features and tailor your ...

Страница 16: ...ll sound during a screen self test This allows you to test the system without causing an alarm To test the Control Panel is receiving a signal do one of the following on each accessory that you want to test 1 Key Pad Press button 8 and 9 together on the Key Pad 2 For all other Accessories Press the test learn button on the accessories A chime will sound and the display will show you which device i...

Страница 17: ...Entry 24 Hour DC only The following devices have a fixed emergency zone type Smoke Detector Key Fob Button Panic Button Key Pad 2 red buttons Zone Type List Burglar When the system is armed and a device is triggered the alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be ignored when the syste...

Страница 18: ...e P Backspace and delete The name can be erased by clearing the display by pressing X repeatedly followed by 3 4 Press 3 when completed to confirm the name and return to the device list Remove Device To delete a device choose remove device in the Edit device menu A list of all programmed devices will be shown 1 Use st keys to select the device you wish to delete and press 3 2 The selected device w...

Страница 19: ...assword is used to configure the Control Panel and to disarm the system To disarm press the disarm key followed by your PIN code To enter the program menu press the st key enter a PIN code followed by 3 Up to 6 PIN codes can be stored 1 Select PIN Code then press 3 a list of 6 PIN codes will be shown occupied codes are shown with The list can be scrolled up and down using thest keys 2 Select the c...

Страница 20: ... The length of the alarm can be set from 1 to 10 minutes in 1 minute increments with this setting 3 minutes is the factory default Panel Siren You can disable the Control Panel s built in siren with this setting Siren on is the factory default Jamming Det Enable or disable Jamming Interference detection on the Control Panel Confirmed by pressing the 3 key Default setting is Disable recommended KF ...

Страница 21: ... to enter a new number confirm by pressing 3 3 Enter your phone number and confirm by pressing 3 Press Up arrow key for key insert 3 seconds time gap useful for switchboard and Down arrow key for the key Errors can be corrected by pressing P to backspace pressing P repeatedly will take you back the telephone number list Telephone numbers can be deleted in the same manner Rec Address This menu allo...

Страница 22: ...press the disarm key followed by a PIN code on the Control Panel and Key Pad You can also tap the contactless tag on the panel to disarm The Key Fob only will only disarm the system during entry time after an entry or away entry Door Window Contact or PIR Motion Detector has been triggered 2 The Control Panel will sound a long beep The External Siren will beep twice and the strobe will flash side ...

Страница 23: ...or 15 seconds before dialling the preset phone numbers After dialling the Control Panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the message by pressing 9 on their teleph...

Страница 24: ...d for 1 hour after which it will automatically arm again If longer is needed to fit the Siren then simply repeat the steps above Leave the Control Panel in programming mode to stop the system responding to tampers If the Control Panel automatically times out re enter programming mode again i Enabling the system tamper After mounting the External Siren and detectors please enable the system tamper ...

Страница 25: ...ollowed by the 7 key to set the Key Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the ...

Страница 26: ...y Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the same PIN code that is set for the ...

Страница 27: ...ns To check the fault log see page 25 PIR Motion Detector Battery Change When the battery is low the LED will flash when any motion is detected The batteries are changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Loosen the case screw and remove PIR from base to reveal the batteries 3 Insert 3 x new AAA alkaline batteries observing correct polarity The PIR LED...

Страница 28: ...y is changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Unscrew the two Key Pad case screws and remove Key Pad back to reveal battery 3 Using a screwdriver gently lever out the old battery 4 Insert new CR2032 coin cell battrey with the side uppermost 5 Press battery into holder firmly with finger and thumb until a click is heard see picture below 6 Press a num...

Страница 29: ... random fluctuations and responds to genuine motion across field of view it is less sensitive walking directly towards it PIR Motion Detector gives false alarms Check pets have no access to protected area Check that the PIR Motion Detector is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR Motion Detector is not mounted above convector heaters or pointing di...

Страница 30: ...dividual fault messages will be displayed sequentially at 2 second intervals IMPORTANT Please enter the programming menu first before swapping the batteries otherwise you will trip the system tamper alarm Press the pq and enter your user PIN code followed by pressing 3 Stay in the programming menu Then disconnect the relevant accessory and replace batteries If the Control Panel times out and retur...

Страница 31: ... scenario Disarm GREEN Away Arm RED Home Arm YELLOW Exit Away Arm Entry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action Away Entry Door Chime Start Entry Time No action No acti...

Страница 32: ...lier of locking solutions dedicated to satisfying end user needs for security safety and convenience PACKAGING FR An ASSAABLOY Group brand Yale Intruder Alarm v08 YaleSecurityUK YaleSecurity YaleUK Customer Service At Yale we know the importance of providing security products that are easy to install and use However should you have any questions or experience a problem with your purchase please vi...