G-5400B/-5600B Az-

e

l

 Rotator

  Connect the supplied DC cable to a source of 12 

VDC. The red lead connects to the Positive (+) DC 

terminal, and the black lead connects to the Negative  

(–) DC terminal. The 

GS-232B

 requires 70 mA. The 

supplied cable has a 500-mA fast-blow fuse. Use only 

the same type fuse for replacement.

  Plug the coaxial power connector into the 

DC 12V

 

jack on the 

GS-232B

 rear panel.

  Connect the supplied Control cable (“Dual 5-pin” 

 

  “DIN”) between the rotator’s controller and 

GS-232B

Be careful to match the “

AZ

” and “

EL

” labels on the 

cable with the same labels on the rear panel of the 

GS-232B

 (Figure 2).

G-400/G-500 or G-400/G-550 & pair of GX-500

  Connect the supplied DC cable to a source of 12 

VDC. The red lead connects to the Positive (+) DC 

terminal, and the black lead connects to the Negative  

(–) DC terminal. The 

GS-232B

 requires 70 mA. The 

supplied cable has a 500-mA fast-blow fuse. Use only 

the same type fuse for replacement.

  Plug the coaxial power connector into the 

DC 12V

 

jack on the 

GS-232B

 rear panel.

  Connect the 5-pin to 5-pin cable (supplied with the 

GX-500

; requires two sets) between the 

GX-500

(s) 

and  

GS-232B

 (Figure 3).

GX-500

Figure 3

To DC 12V Power Source

To Serial port of the computer

To Elevation

Controller

To Elevation

Rotator

To Azimuth Controller

To Azimuth Rotator

GX-500

Figure 2

To DC 12V Power Source

To Serial port  of the computer

G-5400B/-5600B

or G-5500

A

z

/E

l

 Rotator

Содержание GS-232B

Страница 1: ...ators YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 90630 U S A YAESU UK Unit 12 Sun Valley Business Pa...

Страница 2: ......

Страница 3: ...ically to support it software is not supplied by Yaesu In addition to reading and setting antenna angle and ro tation speed the firmware includes clocked positioning G eneral D escription routines to...

Страница 4: ...On The Equipment ON power Stand by Direct current S pecifications Connector Pinouts Serial I O 9 pin DB 9 connector RS 232C connector Pin 2 Tx Data Pin 3 Rx Data Pin 5 Signal Ground Pin 7 RTS Pin 8 C...

Страница 5: ...ug 1 pc Hook loop fasteners for mounting 1 pc 1 G 800DXA G 1000DXA G 2800DXA G 800DXC G 1000DXC and G 2800DXC 2 G 5400B G 5600B and G 5500 A ccessories O ptions Available Options C 1000 Connection Cab...

Страница 6: ...source of 12 VDC The red lead connects to the Positive DC terminal and the black lead connects to the Negative DC terminal The GS 232B requires 70 mA The supplied cable has a 500 mA fast blow fuse Us...

Страница 7: ...anel of the GS 232B Figure 2 G 400 G 500 or G 400 G 550 pair of GX 500 Connect the supplied DC cable to a source of 12 VDC The red lead connects to the Positive DC terminal and the black lead connects...

Страница 8: ...B Figure 4 Replace the Top Cover Connect the supplied DC cable to a source of 12 VDC The red lead connects to the Positive DC terminal and the black lead connects to the Negative DC terminal The GS 23...

Страница 9: ...on Within 15 seconds of swithing the GS 232B s power press the Enter key several times to adjust the GS 232B s data baud rate to the Computer s data baud rate If the computer is successul to setting t...

Страница 10: ...r s dis play should show AZ aaa where aaa is a three digit number which indicates the azimuth heading in degrees Adjust the OUT VOL ADJ potentiometer on Control ler rear panel so as to get a reading o...

Страница 11: ...From the Controller panel set the Rotator fully clock wise to the right Press F F and Enter on the computer keyboard to activate the Control Interface s azimuth A D converter calibration routine The c...

Страница 12: ...ntroller panel set the Azimuth Rotator fully clockwise to the right Press F F and Enter on the computer keyboard to activate the Control Interface s azimuth A D converter calibration routine The compu...

Страница 13: ...or to full scale 180 right horizon Press F2 F 2 and Enter on the computer keyboard to activate the Control Interface s elevation A D converter calibration routine The computer will display AZ aaa EL e...

Страница 14: ...of 450 on the computer s display This reading 450 360 degrees 90 degrees cor responds to the actual beam heading you established when you pointed the azimuth rotator fully clockwise Press Enter on the...

Страница 15: ...and Enter on the computer keyboard to activate the Control Interface s elevation A D converter calibration routine The computer will display AZ aaa EL eee where eee is a three digit number which indi...

Страница 16: ...ress F2 F 2 and Enter on the computer keyboard to activate the Control Interface s elevation A D converter calibration routine The computer will display AZ aaa EL eee where eee is a three digit number...

Страница 17: ...Keep in mind that all commands require that the Enter key be pressed after the command letter or 0Dh be sent by a control program although we will not repeat this when discussing the commands Also not...

Страница 18: ...scale send command adjust OUT VOL ADJ trimmer on rear of controller or GX 500 elevation adapter until the returned data is 180 or 450 0nn 180 for elevation Press Enter on the computer keyboard to exi...

Страница 19: ...m eters are present the first one is interpreted by the Control Interface as the rotation interval sss not an angle Valid ranges are 001 to 999 for sss and 000 to 360 or 450 depending on rotator type...

Страница 20: ...lways be supplied when chang ing elevation and that a setting point consists of a pair of angles Waaa eee Turn to aaa degrees azimuth and eee degrees elevation where aaa is a three digit number betwee...

Страница 21: ...kwise Rotation L Counter Clockwise Rotation A CW CCW Rotation Stop C Antenna Direction Value M Antenna Direction Setting MXXX M Time Interval Direction Setting MTTT XXX XXX XXX TTT Step value XXX Hori...

Страница 22: ...ibration F2 Full Scale Calibration B Elevation Antenna Direction Value Command List Returned by H3 Command HELP COMMAND 3 P45 Set_mode 450 Degree P36 Set_mode 360 Degree Z Swicth N Center S Center MOD...

Страница 23: ...Shinagawa ku Tokyo 140 0002 Japan Applicable Standards This equipment is tested to and conforms to the essential requirements of directive as included in following standards SAFETY 1999 5 EC Art 3 1 a...

Страница 24: ...Copyright 2016 YAESU MUSEN CO LTD All rights reserved No portion of this manual may be reproduced without the permission of YAESU MUSEN CO LTD 1606S DO Printed in Japan...

Отзывы: