CAT Data Protocol
Serial data is passed via the
CAT
jack on the rear
panel at a transfer rate set via Menu #37 (4800, 9600,
or 57600 bps). While data is being transferred, the
CAT
icon on the LCD will appear momentarily, dis-
appearing when the data flow is terminated.
All commands sent from the computer to the trans-
ceiver consist of five-byte blocks, with up to 200 ms
between each byte. The last byte in each block is the
instruction opcode
, while the first four bytes of each
block are arguments (either parameters for that instruc-
tion, or dummy values required to pad the block out to
five bytes). Each byte consists of 1 start bit, 8 data
bits, no parity bit, and two stop bits.
CAT
D
ATA
B
YTE
F
ORMAT
CAT
5-B
YTE
C
OMMAND
S
TRUCTURE
There are 25 instruction opcodes for the FT-847, listed
in the chart on previous page. Many of these opcodes
are On/Off toggle commands for the same action (e.g.
“PTT On” and “PTT Off”).Most of these commands
require some parameter or parameters to be set. Irre-
spective of the the number of parameters present, ev-
ery Command Block sent
must
consist of five bytes.
Accordingly, any
CAT
control program must construct
the five-byte block by selecting the appropriate instruc-
tion opcode, organizing the parameters as needed, and
providing unused “dummy” argument bytes to pad the
block to its required five-byte length (the dummy bytes
can contain any value). The resulting five bytes are
then sent, opcode last, from the computer to the FT-
847 CPU via the computer’s serial port and the
transceiver’s
CAT
jack.
All
CAT
data values are hexadecimal.
Note that, unlike most other Yaesu transceivers, the
FT-847 serial data cable is a “null modem” (“crossed”)
type, not a “straight” serial data cable.
CAT
(C
OMPUTER
A
IDED
T
RANSCEIVER
)
S
YSTEM
P
ROGRAMMING
Constructing and Sending
CAT
Commands
Example #1:
Set the Main VFO frequency to 439.70 MHz
r
Per the
CAT
command table, the opcode for
“S
ET
F
REQUENCY
TO
M
AIN
B
AND
” is
01
(set by
the “
P1
” command byte). Placing the opcode
into the 5th data bit position, we then enter the
frequency into the first four data bit positions:
Send these five bytes to the transceiver, in the
order shown above.
Example #2:
Turn the “S
ATELLITE
” Mode “O
N
”
r
Per the CAT command table, the opcode for “S
ET
S
ATELLITE
M
ODE
O
N
” is
4E
(hex). Placing the
opcode into the 5th data bit position, we then
enter dummy values into all other parameter lo-
cations:
Send these five bytes to the transceiver, in the
order shown above.
Start
B it
0
1
2
3
4
5
6
7
S top
B it
S top
B it
Command
Data
L.S.D.
Parameter
1
Parameter
2
Parameter
3
Parameter
4
M.S.D.
C
OMMAND
Freq.
(Hz)
D1
Freq.
(Hz)
D1
Freq.
(Hz)
D1
Freq.
(Hz)
D1
67.0
3F
94.8
1D
131.8
0 9
186.2
0 4
69.3
3 9
97.4
3 A
136.5
1 8
192.8
1 3
71.9
1F
100.0
0D
141.3
0 8
203.5
0 3
74.4
3 E
103.5
1C
146.2
1 7
210.7
1 2
77.0
0F
107.2
0C
151.4
0 7
218.1
0 2
79.7
3D
110.9
1 B
156.7
1 6
225.7
11
82.5
1 E
114.8
0 B
162.2
0 6
233.6
0 1
85.4
3C
118.8
1 A
167.9
1 5
241.8
1 0
88.5
0 E
123.0
0 A
173.8
0 5
250.3
0 0
91.5
3 B
127.3
1 9
179.9
1 4
−
−
CTCSS Tone Data