23
FT-7100M Operating Manual
O
PERATION
T
RANSMISSION
To transmit, simply close the
PTT
(
P
ush
T
o
T
alk) switch on the microphone when the
frequency is clear. Hold the microphone approximately 25 mm (1”) from your mouth, and
speak into the microphone in a normal voice level. When your transmission is complete,
release the
PTT
switch; the transceiver will revert to the receive mode.
During transmission, the “main” band
BUSY/TX
indicator changes from Green to Red, and
the S&PO meter segments rise up according to the power output selected.
Power Output Setting
Four power output levels are available on this transceiver: 5 watts (LOW), 10 watts (MID 2),
20 watts (MID 1) and 50 watts (VHF) or 35 watts (UHF) on HIGH.
To change the power level, press the [
LOW
] key. Each time you press the [
LOW
] key, the
new power level will be displayed for a few seconds, then the regular display mode will
reappear.
The power level can be set independently for each band. Also, the power level may be stored
in a memory register, if desired.
PTT Locking
The
PTT
circuitry may be locked out, so as to prevent unau-
thorized or otherwise undesired transmission.
To lock out the
PTT
circuitry and thus prevent transmission:
1. Press and hold in the [
BAND
] key for 1/2 second to acti-
vate the “Menu” mode.
2. Rotate the
Main Dial
knob to select Menu # 16 (
LOCKT
).
3. Press the [
BAND
] key momentarily to enable changing of this Menu item.
4. Rotate the
Main Dial
knob to select the desired lock mode:
BAND A
:
PTT
will be disabled on VHF only;
BAND B
:
PTT
will be disabled on UHF only;
BOTH
:
PTT
will be disabled on both the VHF and UHF bands; or
OFF
:
PTT
lock feature is off.
5. Press and hold in the [
BAND
] key for 1/2 second to save the new setting and exit to
normal operation.
To cancel the
PTT
lock feature, select “
OFF
” in step 4 above.
PTT Lock Active
Содержание FT-7100M