background image

To be retained

User’s Manual

Table of 
Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
Safety Precautions . . . . . . . . . . . . . . . . . . . . . .  1
When Using Outside of Japan. . . . . . . . . . .  9
Names and Functions of Components. . . . 10
Before Use. . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
How to Use . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

After Treatment . . . . . . . . . . . . . . . . . . . . . .  26
Additional Information . . . . . . . . . . . . . . . .  28

z

 Troubleshooting . . . . . . . . . . . . . . . . . . .  28

z

 Frequently Asked Questions . . . . . . . . .  30

z

 Product Specifications . . . . . . . . . . . . . .   31

After-sales Service . . . . . . . . . . . . . . . . . . . .  32

Home Beauty Device

M18

Photo PLUS Shiny

Содержание Photo PLUS Shiny

Страница 1: ...When Using Outside of Japan 9 Names and Functions of Components 10 Before Use 12 How to Use 15 After Treatment 26 Additional Information 28 z Troubleshooting 28 z Frequently Asked Questions 30 z Produ...

Страница 2: ...o keep this User s Manual in an accessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person z Classifications of Precautions z Symbols...

Страница 3: ...nhealthy skin blemishes caused by physical irritation If you are experiencing skin irritation or redness due to sunburn If you are severely fatigued If you are physically unwell If you are under the i...

Страница 4: ...are accessible to children A location where there is exposure to oil smoke or steam A location with drastic temperature changes for example near an air conditioner or heater Failure to comply may lea...

Страница 5: ...iscontinue use and request an inspection Failure to comply may lead to a fire or electric shock Mandatory compliance Do not use or charge the device in the bathroom or near a bathtub shower sink or ot...

Страница 6: ...ation of heat a fire or explosion Fire hazard Explosion CAUTION Use and storage Do not press the device strongly or use it intensively on a single area Pressing the device stronger than necessary or u...

Страница 7: ...rniture while it is switched on Be sure to turn the device off after use Failure to comply may cause injuries or damages the furniture Do not allow the device to come into a contact with another elect...

Страница 8: ...ately if the treatment does not agree with your skin Be sure to use the device only for the following lengths of time Daily Care DAILY Mode up to 3 minutes per treatment once a day Weekly Care CLEAN M...

Страница 9: ...inserted into the USB port Failure to comply may cause a fire an electric shock or a failure of the device Be sure to use the dedicated USB charging cable supplied with the product Plug the AC adapte...

Страница 10: ...sure to check the plug configuration and the voltage of the power outlet before use Mandatory compliance WARNING The plug configuration and voltage may vary depending on the region and the type of acc...

Страница 11: ...and Functions of Components Main Body Front view Back view Electrode head Power Level button Charging terminal Mode button Remaining battery level indicator Hand Electrode LED Lamps Mode lamp Level i...

Страница 12: ...Refer to pages 16 and 17 for each mode s operating time Timer When treatment in a certain mode is completed the device will emit rapid beeping sounds and the following mode indicator flashes Standby...

Страница 13: ...he charging base that is connected to the USB charging cord as shown in the diagram Using a household power outlet Remaining battery level indicator Charging terminal Charging terminal Charging termin...

Страница 14: ...TTENTION Charging The remaining battery level indicator flashes in white When charging is complete The remaining battery level indicator lights up in white for 5 seconds and then turns off Charging ti...

Страница 15: ...ess stinging sensation or other abnormality occurs at the pre testing area immediately stop the pre test Check carefully to make sure that there are no skin abnormalities before using the device Stop...

Страница 16: ...he warmth of the RF radio frequency changes depending on the type of skincare products used and the skin s condition at the time of treatment Do not use on the upper eyelids except in COOL Mode or aro...

Страница 17: ...n only during ion emission Approx 3 minutes 3 levels 2 to 3 times per week DYHP Approx 5 minutes EYE CARE RF DYHP LED Red Approx 2 minutes 3 levels Daily Care Weekly Care With a cotton pad Either with...

Страница 18: ...n 4 2 Do not use on the same day as Weekly Care Mode except in EYE CARE Mode 3 If you are concerned about dryness of the skin around the eyes we recommend using the device 5 times a week 4 We recommen...

Страница 19: ...electrode head please use a larger and thinner piece of cotton Because thick cotton pads are difficult to fix in place split them in half before use If the cotton pad is too thick the thermal action...

Страница 20: ...trode head if necessary and apply skin lotion to the cotton pad COOL Mode can be used over makeup 3 Turn on the device Hold down the Power Level button hold down the button for approx 3 seconds or lon...

Страница 21: ...mode light up For information about each mode refer to Modes pages 16 17 Mode button Mode lamp DAILY Mode Daily Care Press and hold the mode button to change the mode CLEAN Mode COOL Mode Weekly Care...

Страница 22: ...utton the device will beep once and the level will change Level 1 the minimum Level 2 Be sure to start using the device from Level 1 Do not use the device at a level which pain can be felt ATTENTION L...

Страница 23: ...How to use the device on your skin pages 23 25 to learn how to move the device Refer to pages 16 and 17 for each mode s operating time During use make sure the electrode head is firmly touching the sk...

Страница 24: ...de head comes in a contact with your skin Be sure to move the device over the skin as you use it except when using the device in EYE CARE Mode and COOL Mode Using the device continuously on the same a...

Страница 25: ...ot treat Areas you should not treat Move the electrode head over the skin in the direction of the arrows shown below The LED light can be used to treat areas around the eyes and the upper eyelids DYHP...

Страница 26: ...your face from the inner corner to the outer corner of the eye as if stamping on the skin Press Release Move electrode head Press down on the skin for approx 3 seconds If you are concerned about dryn...

Страница 27: ...ene nail polish remover kerosene chemicals or polishing powder WARNING When cleaning the device check to make sure it is not charging and that the power is switched off 1 To clean the device and elect...

Страница 28: ...he reach of children Maintenance and Inspections If you have not used the device for an extended period inspect it carefully and check that it works properly and safely before using it again If the de...

Страница 29: ...for COOL Mode COOL Mode is not very cool COOL Mode is being used continuously Turn off the device and wait at least 30 minutes before using it again The device is being used in an environment where t...

Страница 30: ...r I cannot feel any warmth The device is in standby or Auto off status page 11 Press the mode button to start the mode of your choice page 16 The skin lacks moisture Moisturize your skin with lotion b...

Страница 31: ...day 5 times a week COOL Mode 3 minutes per treatment once a day 2 to 3 times a week Do not use Daily Care and Weekly Care except in EYE CARE Mode on the same day The above is also recommended if you...

Страница 32: ...icon rubber Electrode head PET resin and stainless steel Hand electrode Stainless steel Charging time Approx 3 hours The actual charging time will differ depending on the remaining battery level the c...

Страница 33: ...information on disposing of batteries see Disposing of the battery and Removing the battery below page 33 The lithium ion battery used in this product is a valuable recyclable resource After sales ser...

Страница 34: ...screw cover and the rubber sheet with a thin sharp object then remove the screw Screw cover 2 Remove the bottom housing 3 Remove the back cover Removing the battery Screw Rubber sheet Screw Bottom co...

Страница 35: ...the battery Battery Caution This image is intended to be used for disposing of the product not repairing it Do not disassemble the product except for disposal Failure to comply may cause a fire elect...

Страница 36: ...untries and regions outside Japan please contact the store where you purchased your product for any inquiries Alternatively check the YA MAN GLOBAL Official Website https www ya man com en Official we...