Table 4 - Lightning Protection Efficiency for 70 ft (21 m) Towers
Isolated Flat Land
Hill or Knoll
Non-Isolated Flat Land
Ng
efficiency
efficiency
efficiency
Nc =
1/100
Nc =
1/1000
Nc =
1/10000
Nc =
1/100
Nc =
1/1000
Nc =
1/10000
Nc =
1/100
Nc =
1/1000
Nc =
1/10000
0.01
0.001
0.0001
0.01
0.001
0.0001
0.01
0.001
0.0001
1
0.352
0.935
0.994
0.676
0.968
0.997
-0.296
0.870
0.987
2
0.676
0.968
0.997
0.838
0.984
0.998
0.352
0.935
0.994
3
0.784
0.978
0.998
0.892
0.989
0.999
0.568
0.957
0.996
4
0.838
0.984
0.998
0.919
0.992
0.999
0.676
0.968
0.997
5
0.870
0.987
0.999
0.935
0.994
0.999
0.741
0.974
0.997
6
0.892
0.989
0.999
0.946
0.995
0.999
0.784
0.978
0.998
7
0.907
0.991
0.999
0.954
0.995
1.000
0.815
0.981
0.998
8
0.919
0.992
0.999
0.960
0.996
1.000
0.838
0.984
0.998
9
0.928
0.993
0.999
0.964
0.996
1.000
0.856
0.986
0.999
10
0.935
0.994
0.999
0.968
0.997
1.000
0.870
0.987
0.999
11
0.941
0.994
0.999
0.971
0.997
1.000
0.882
0.988
0.999
12
0.946
0.995
0.999
0.973
0.997
1.000
0.892
0.989
0.999
13
0.950
0.995
1.000
0.975
0.998
1.000
0.900
0.990
0.999
14
0.954
0.995
1.000
0.977
0.998
1.000
0.907
0.991
0.999
15
0.957
0.996
1.000
0.978
0.998
1.000
0.914
0.991
0.999
16
0.960
0.996
1.000
0.980
0.998
1.000
0.919
0.992
0.999
17
0.962
0.996
1.000
0.981
0.998
1.000
0.924
0.992
0.999
18
0.964
0.996
1.000
0.982
0.998
1.000
0.928
0.993
0.999
19
0.966
0.997
1.000
0.983
0.998
1.000
0.932
0.993
0.999
20
0.968
0.997
1.000
0.984
0.998
1.000
0.935
0.994
0.999
30
0.978
0.998
1.000
0.989
0.999
1.000
0.957
0.996
1.000
40
0.984
0.998
1.000
0.992
0.999
1.000
0.968
0.997
1.000
50
0.987
0.999
1.000
0.994
0.999
1.000
0.974
0.997
1.000
60
0.989
0.999
1.000
0.995
0.999
1.000
0.978
0.998
1.000
70
0.991
0.999
1.000
0.995
1.000
1.000
0.981
0.998
1.000
The Lightning Protection Level
Refer to
Table 5
, the “Lightning Protection Level” and using the Efficiency (E) determine the Lightning
Protection Level (LPL) and corresponding peak lightning current discharge capability.
Lightning Protection Level 1 provides highest level of protection and Lightning Protection Level 4, the
lowest level of protection.
Table 5 - Lightning Protection Level
Efficiency
Lightning Protection Level
E > 0.980
Lightning Protection Level 1
with additional measures
0.95 < E < = 0.98
Lightning Protection Level 1
0.90 < E < = 0.95
Lightning Protection Level 2
0.80 < E < = 0.90
Lightning Protection Level 3
0 < E < = 0.80
Lightning Protection Level 4
Содержание Skystream 3.7
Страница 37: ...Skystream Owner s Manual 3 CMLT 1054 Rev O XCO 1191 Pg 37 SKYSTREAM 3 7 Appendix B Tower Grounding...
Страница 44: ...Skystream Owner s Manual 3 CMLT 1054 Rev O XCO 1191 Pg 44 Figure 4 Concrete Encased Electrode...
Страница 45: ...Skystream Owner s Manual 3 CMLT 1054 Rev O XCO 1191 Pg 45 SKYSTREAM 3 7 Appendix C LIGHTNING PROTECTION...
Страница 53: ...Skystream Owner s Manual 3 CMLT 1054 Rev O XCO 1191 Pg 53 SKYSTREAM 3 7 Appendix D CERTIFICATION COMPLIANCE...
Страница 55: ...Skystream Owner s Manual 3 CMLT 1054 Rev O XCO 1191 Pg 55 2 CE Declaration of Conformity Europe...