For example:   F-0 → F-1 → F-2   

                            ↑                        ↓ 
                            ←        ←        ←       
3. Password Setting:   

When the LED displays “F-1” and flashes, press “SET” key one time and the unit 
enters the Password Set status. At this moment, the LED displays the pre-set value. 
Press “▲” or “▼” key to change password set value. If the user sets “000” that 
means the unit will be under the status of no password. If the user sets “100” then 
means the unit will be under the password status. Press “SET” key once to finish 
password setting and the unit will backup mode, the user can continue set other 
modes or back from the setting mode.   

4. Fahrenheit and Centigrade (Celsius) temperature selection   

When temperature display window shows "F-4" and blinking, press the "SET" 
button, at this time, the system enters the degrees Fahrenheit and Centigrade 
temperature selection function, indicating the temperature of the window shows the 
current status.   Press "▲" or "▼" key to change the temperature selection status. It 
expressed as degrees Celsius temperature value if set to 

; it shows as degrees 

Fahrenheit temperature if set to 

℉. 

 

OPERATING INSTRUCTIONS 

NOTE: In order to protect the pump during transportation, 

the pump in the 

machine is tightened by the 4 screws under the bottom enclosure. Please unscrew the 
4 screws when the machine is used at the first time

. (See Fig. A). 

 

 

Fig. A 

 

Содержание LF-855D

Страница 1: ...OPERATING MANUAL FOR LF 855D Multi Function SMD Rework System ...

Страница 2: ... ensure that they do not play with appliance Failure to observe the safety regulation will result in a risk of life and limb The manufacturer shall not be liable for damage resulting from misuse of the unit or unauthorized alterations 1 Please unscrew the 4 screws under the bottom enclosure when the unit is used at the first time See the procedure on page13 2 Ensure the voltage rating of the unit ...

Страница 3: ... by pulling the plug not the cable when the unit will remain unused for a longer period of time 7 Do not modify the unit Warning Soldering Desoldering Function Warning Always place the soldering desoldering irons in its original holder when not being used Keep the soldering and desoldering tip and heating element away from the body clothes and flammable material when in operation The soldering and...

Страница 4: ...ning hot after being switch off on some time Ensure that you do not touch the nozzle Do not use if damaged If the pump doesn t work or the rework station becomes faulty discontinue using immediately To comply with safety standards the pump or other part must only be replaced by authorized technicians as special purpose tools are required Only the technician is permitted undertake repairs Use the o...

Страница 5: ...ion the main power will be switched off to sleep mode which cuts power consumption and extends tip life Please note You have to turn off the power switch first and then switch ON again to commence work when the unit goes to Sleep mode IRON WORKING OPTION When the users don t use the soldering or desoldering function or they also set by pressing keys SET at this time the iron which you set will ent...

Страница 6: ...ion Max 700W Weight 7 5kg Solder Power Consumption 90W Temperature Range 100 520 212 896 Sleeping Temperature 100 212 Temperature correction range 99 99 178 178 Default setting 100 F 1 000 F 2 00 F 3 100 F 4 Hot Air Power Consumption 600W Air Flow 1 5 L Min 40L Min Temperature range 100 480 212 896 Air Flow 00 99 Default seting F 1 000 F 2 Temperature 100 Air Flow 00 ...

Страница 7: ...g Function Part 4 Temperature increasing UP 5 Temperature decreasing Down 6 Temp Display 7 Heat indicating light 8 SET Function key Hot Air Function Part 9 Temperature increasing UP 10 Temperature decreasing Down 11 Temp Display 12 Heat indicating light 14 Hot air blow UP 15 Temp Display 16 Hot air blow DOWN ...

Страница 8: ...n the unit will be immediately back from the Parameter Set status For example F 0 F 1 F 2 F 3 F 4 3 Password Setting When the LED displays F 1 and flashes press SET key one time and the unit enters the Password Set status At this moment the LED displays the pre set value Press or key to change password set value If the user sets 000 that means the unit will be under the status of no password If th...

Страница 9: ...mode function after 20min idleness the system will enter the sleep mode automatically the temperature of soldering will go down to 150 302 and the LED displays at 150 and flashes the temperature of desoldering will go down to 200 392 and the LED displays at 200 and flashes Activating the solder wand will disengage the suspend status and the unit will immediately ramp up to the preset temperature T...

Страница 10: ... No password set 1 Increase temperature By pressing key one time the digital will be increase 1 numeral If pressing key over 2 seconds then the digital numerals will be forwarded counting continuously till the temperature up to what you desire to set 2 Decrease temperature By pressing key the same procedure as above AIR FLOW SETTING No password set 1 Increase temperature By pressing key one time t...

Страница 11: ...e setting mode 4 Fahrenheit and Centigrade Celsius temperature selection When temperature display window shows F 4 and blinking press the SET button at this time the system enters the degrees Fahrenheit and Centigrade temperature selection function indicating the temperature of the window shows the current status Press or key to change the temperature selection status It expressed as degrees Celsi...

Страница 12: ...r gun will work at the same time after turning the power switch and then the corresponding temperature LED or wind LED display will be ON and show the value 6 Users can turn off the the Soldering function by pressing the key SET UP then the corresponding LED display will show _ _ _ NOTE It means that the corresponding heater power is cut off At this time the users can only use the hot air function...

Страница 13: ... or daily for light usage Remove any loose build up in the tip retaining assembly to prevent tip freezing Solder tips supplied are iron clad copper and if used properly should maintain optimum life 1 Always tin the tip before returning it to the holder turning off the station or storing it for long periods of time Wipe the tip on a brass cleaner prior to use 2 Keeping the iron set at high temperat...

Страница 14: ...ONS 1 Make sure both heater and nozzle are cool before attaching the nozzle 2 Caution High Temperature Operation Both nozzle and hot air are extremely hot and can cause burns Never touch the nozzle and heater assembly or allow the hot air to blow against your skin Initially the iron may emit white smoke but this will soon dissipate Operation Setup 1 Select the Nozzle that matches the size of the I...

Страница 15: ...lder After removing the IC cleaning the remaining solder chips with a wick or desoldering tool Note For SOP PLCC etc would recommend by using tweezers iron to desolder QFP Soldering 1 Apply the solder paste Apply the proper quantity of solder paste and flux preferably no clean and place install the SMD on the PCB 2 Preheat SMD 3 Soldering Heat the lead frame evenly 4 Washing When soldering is comp...

Страница 16: ...sembly the heater according the backward procedure See Fig 3 SPARE PART Part No 79 460012 Heating element 120Vac 60Hz 600W Part No 79 560012 Heating element 230 240Vac 50Hz 600W INTERCHANGEABLE ACCESSORY 1 INTERCHANGEABLE TIPS Soldering tips for SIA HF 90 I B 1C 2C 3C k 1 6D 4C 4 2D ...

Страница 17: ...16 2 INTERCHANGEABLE NOZZLES ...

Отзывы: