background image

TriOxmatic

®

700 (SW)

44

ba25307e06

07/2015

Accuracy when going to

press

The use of advanced technology and the high quality standard of our 
instruments are the result of continuous development. This may result 
in differences between this operating manual and your instrument. 
Also, we cannot guarantee that there are absolutely no errors in this 
manual. Therefore, we are sure you will understand that we cannot 
accept any legal claims resulting from the data, figures or descriptions.

Note

The latest version of the present operating manual can be found on the 
Internet under www.WTW.com.

Copyright

©

 Weilheim 2005, WTW GmbH

Reprinting - even as excerpts - is only allowed with the explicit written 
authorization of WTW GmbH, Weilheim.
Printed in Germany.

Содержание WTW SensoLyt 700 SW

Страница 1: ...ba25307e06 07 2015 TriOxmatic 700 TriOxmatic 700 SW 43 Operating manual D O sensor TriOxmatic 700 TriOxmatic 700 SW...

Страница 2: ...nt Also we cannot guarantee that there are absolutely no errors in this manual Therefore we are sure you will understand that we cannot accept any legal claims resulting from the data figures or descr...

Страница 3: ...eneral information on calibration 54 4 2 2 Calibration in water vapor saturated air 55 4 3 Function check 56 5 Maintenance cleaning disposal and replacement 59 5 1 General maintenance instructions 59...

Страница 4: ...Contents TriOxmatic 700 SW 46 ba25307e06 07 2015...

Страница 5: ...he TriOxmatic 700 SW Fig 1 1 Structure of the D O sensor example TriOxmatic 700 1 Protective hood 2 WP 600 membrane cap 3 Electrode unit 4 Shaft Electrode unit 5 Gold working electrode cathode 6 Insul...

Страница 6: ...tions TriOxmatic 700 SW Stationary measurements in seawater aquaculture 1 3 Instrument identification Instrument identification The instrument designation end of name 99 for SW model is impressed on t...

Страница 7: ...signal word e g Caution indicates the level of the danger Warning indicates instructions that must be followed precisely in order to prevent serious dangers to persons Caution indicates instructions t...

Страница 8: ...g the operation and transport of the sensor Protect the sensor particularly against frost or overheating Safe operation If safe operation is no longer possible the sensor must be taken out of operatio...

Страница 9: ...00 SW connection cable has a screw plug to be connected to the Oxi input socket of a measuring transmitter It is connected to the terminal strip of measuring transmitters without an Oxi input socket v...

Страница 10: ...ng transmitter is operating Precision measurements Recommendation In order to carry out precision measurements leave the sensor to polarize for a longer period of time e g overnight and recalibrate it...

Страница 11: ...measured value is available immediately on submersing Note Do not suspend the sensor on the sensor connection cable Use a sensor holder or armature Information on this and other TriOxmatic 700 SW acc...

Страница 12: ...bration takes place in water vapor saturated air To do so position the sensor approx 2 cm above a water surface for example in a narrow bucket or similar container with water In the case of air temper...

Страница 13: ...t sparkles Then immerse the sensor in a vessel with air saturated water calibrating position and calibrate as described above 1 If necessary clean the sensor and membrane and dry the membrane see sect...

Страница 14: ...ration Function check in water vapor saturated air Proceed as follows Note If there are large temperature differences between the sample and the air above the surface of the water a balancing period o...

Страница 15: ...on required by the user Measured values outside the required precision If the measured value lies outside the range of precision required by the user clean the sensor shaft and membrane see section 5...

Страница 16: ...Measuring Operation TriOxmatic 700 SW 58 ba25307e06 07 2015...

Страница 17: ...shaft and membrane For normal operation e g municipal wastewater cleaning and calibration are strongly recommended in the case of pollution according to visual check in the case of suspected incorrect...

Страница 18: ...brane is not damaged e g by sharp edged objects by laying it on sharp stones etc 1 Pull the sensor out of the sample 2 Get rid of any coarse contamination on the sensor e g brush it off in a bucket of...

Страница 19: ...ance cleaning disposal and replacement 61 ba25307e06 07 2015 7 Screw the protective hood back on again 8 If necessary carefully dry the membrane with a lint free paper towel 9 Calibrate the sensor see...

Страница 20: ...ng electrode and silver counter electrode have been cleaned Caution Before unscrewing the membrane cap disconnect the sensor from the instrument Otherwise undesirable electrochemical reactions can occ...

Страница 21: ...se thoroughly with water and consult a doctor During working activities always wear suitable protective gloves and protective goggles face shield Follow the safety datasheet 5 Unscrew the membrane cap...

Страница 22: ...15 8 Thoroughly rinse the sensor head with electrolyte solution 9 Fill a new WP 600 membrane cap with ELY A electrolyte solution see section 5 8 MAINTENANCE EQUIPMENT AND REPLACEMENT PARTS 10 Throw aw...

Страница 23: ...protective goggles face shield Follow the safety datasheet 11 Remove any air bubbles by carefully tapping the membrane cap 12 Screw the membrane cap onto the shaft while holding the sensor at an angl...

Страница 24: ...period of time e g overnight and recalibrate it the following day Note In the following cases you must refill the sensor once more If there are large air bubbles If there are air bubbles on the gold w...

Страница 25: ...rochemical reactions can occur that may lead to the destruction of the sensor Preparatory activities Caution The ELY A electrolyte solution irritates eyes skin and mucus membranes If it comes into con...

Страница 26: ...Maintenance cleaning disposal and replacement TriOxmatic 700 SW 68 ba25307e06 07 2015 6 Rinse the sensor head with tap water...

Страница 27: ...le the sensor to be calibrated again For safety however we recommend to also clean the silver counter electrode see section 5 4 2 and to use a new membrane cap afterwards 1 Moisten the gold working el...

Страница 28: ...er counter electrode in a beaker Caution The reference electrode must not come into contact with the cleaning solution under any circumstances This could destroy the reference electrode and cause the...

Страница 29: ...screw cap from the safety cap of the cleaning attachment 4 Fill the screw cap with RL AG Oxi cleaning solution see section 5 8 MAINTENANCE EQUIPMENT AND REPLACEMENT PARTS 5 Screw the sensor with the...

Страница 30: ...iOxmatic 700 SW 72 ba25307e06 07 2015 7 Unscrew the screw cap 8 Thoroughly rinse the electrode unit with the safety cap on with deionized water 9 Unscrew the safety cap 10 Rinse the sensor head and el...

Страница 31: ...deionized water for at least an hour 12 Carefully shake off the drops of water 13 Fill a new WP 600 membrane cap and screw it on see section 5 3 CHANGING THE ELECTROLYTE AND MEMBRANE CAP 14 Connect t...

Страница 32: ...nder any circumstances This could destroy the reference electrode and cause the sensor to become defective 1 Wipe the silver counter electrode with a lint free paper towel and carefully remove any loo...

Страница 33: ...a25307e06 07 2015 4 Leave the cleaning solution to work for 1 hour 5 Rinse the sensor head and electrode unit several times with deionized water 6 Water the sensor head and electrode unit in deionized...

Страница 34: ...3 addition of 1 mg l of a cobalt II salt accelerates the removal of oxygen from the solution The sensor should be in operation for at least 1 hour before the inspection Test procedure 8 Fill a new WP...

Страница 35: ...ee chapter 7 TECHNICAL DATA The sensor may be stored in any position 5 7 Disposal We recommend to dispose of the sensor without the membrane cap as electronic refuse Caution The ELY A electrolyte solu...

Страница 36: ...tion Model Order no Accessory kit 2 replacement membrane caps 50 ml electrolyte solution 50 ml cleaning solution polishing film ZBK 600 202 620 Replacement membrane caps 2 pieces WP 600 2 202 850 Elec...

Страница 37: ...s and recalibrate In the case of contamination that cannot be removed Exchange the membrane cap and electrolyte Cause Remedy Contaminated electrodes or sensor toxification Clean the electrodes see sec...

Страница 38: ...Mechanical damage to the sensor Cause Remedy Membrane head loose Screw the membrane cap tight Membrane does not fit snugly on the gold working electrode Change the membrane cap then recalibrate see s...

Страница 39: ...ly operated 3 electrode system Dimensions Weight without sensor connection cable Membrane Electrolyte Temperature measurement TriOxmatic 700 SW Contact screw TriOxmatic 700 59 5 160 40 199 226 38 40 3...

Страница 40: ...rew TriOxmatic 700 SW only Titan Grade 2 Membrane cap Polyoxymethylene POM Membrane Fluorine plastic Sensor head Polyoxymethylene POM Insulator Epoxy polyetheretherketone PEEK Protective hood Polyoxym...

Страница 41: ...if the minimum approach flow is guaranteed Approach flow 5 cm s at 1 measurement accuracy D O concentration 0 0 60 0 mg l D O saturation 0 600 0 1200 mbar pO2 In the case of re commissioning or chang...

Страница 42: ...on technique Connection cable permanently mounted on the sensor Connection to the measuring transmitter via 7 pole screw plug Caution All voltages must be protective low voltages or safety extra low v...

Страница 43: ......