background image

OPERATING MANUAL

ba75539e03 03/2018

IQ S

ENSOR

N

ET

 

MIQ/CHV PLUS

VALVE MODULE FOR COMPRESSED AIR-OPERATED SENSOR CLEANING HEADS

Po

we

r

!

OK

All manuals and user guides at all-guides.com

all-guides.com

Содержание WTW MIQ/CHV PLUS

Страница 1: ...ERATING MANUAL ba75539e03 03 2018 IQ SENSOR NET MIQ CHV PLUS VALVE MODULE FOR COMPRESSED AIR OPERATED SENSOR CLEANING HEADS Power OK All manuals and user guides at all guides com a l l g u i d e s c o...

Страница 2: ...MIQ CHV PLUS 2 ba75539d03 03 2018 Copyright 2018 Xylem Analytics Germany GmbH Printed in Germany All manuals and user guides at all guides com...

Страница 3: ...ts for safe operation 9 2 2 3 Unauthorized use 9 2 3 User qualification 9 3 Installation 10 3 1 Scope of delivery 10 3 2 Mounting for use in the IQ SENSOR NET 10 3 3 Electrical connections General ins...

Страница 4: ...List of contents MIQ CHV PLUS 4 ba75539e03 03 2018 9 Accessories and options 23 All manuals and user guides at all guides com...

Страница 5: ...ructure like the IQ SENSOR NET itself It consists of a system operating manual and the operating manuals of all the components used Please file this component operating manual into the ring binder of...

Страница 6: ...tch can consist of one of the following any relay in the IQ SENSOR NET system the relay of a measuring transmitter with the R option any other switch relay or sensor The valve module is connected with...

Страница 7: ...ity leakproofness and weather resistance It also provides the same wide variety of installation options stacked mounting canopy mounting top hat rail mounting etc Terminal strip The MIQ CHV PLUS has t...

Страница 8: ...if the actions mentioned are not taken 2 1 2 Safety signs on the product Note all labels information signs and safety symbols on the product A warning symbol triangle without text refers to safety inf...

Страница 9: ...tly described in this operating manual example connecting electrical lines to the terminal strip 2 2 3 Unauthorized use The product must not be put into operation if it is visibly damaged e g after be...

Страница 10: ...es a number of options for integrating the MIQ CHV PLUS mechanically and electrically in the system stacked mounting distributed mounting etc The individual types of installation are described in deta...

Страница 11: ...gth required for the installation Always fit all the ends of the wires with wire end sleeves before connecting them to the terminal strip Any wires that are not used and project into the enclosure mus...

Страница 12: ...ble to the cable gland Materials required Wire end sleeves suitable for the connecting wires with suitable crimping tool 1 x cable gland with sealing ring scope of delivery MIQ CHV PLUS Tools Cable st...

Страница 13: ...control line through the left cable gland in the module housing 5 Connect the wires of the valve control line pos 5 in Fig 3 1 to the clamping termination for the valve control line While doing so pay...

Страница 14: ...e enclo sure Otherwise there is a danger that areas safe to con tact could come into contact with dangerous voltages This could result in life threatening electric shock when working with the IQ SENSO...

Страница 15: ...of line concerned is free of pressure The compressed air glands in the housing may only be opened by a service technician authorized by WTW 1 MIQ CHV PLUS IQ SENSOR NET Put the IQ SENSOR NET system in...

Страница 16: ...ink of the valve output with a sensor set the valve output check the state of the valve output Functions for the valve output Valve output Cleaning Setting of the cleaning procedure in the menu Settin...

Страница 17: ...2018 5 Maintenance and cleaning 5 1 Maintenance The MIQ CHV PLUS requires no special maintenance 5 2 Cleaning The cleaning of IQ SENSOR NET components is described in the IQ SENSOR NET system operatin...

Страница 18: ...Q SENSOR NET See the chapter WHAT TO DO IF in the system manual Error in triggering Perform the function check according to section 3 6 If the valve does not switch check the control loose clamping co...

Страница 19: ...Mechanical construction 144 0 115 0 70 0 144 0 45 0 72 0 52 2 11 0 16 5 Lateral view Front view Rear view 137 0 137 0 100 148 Stack mounting Maximum number of modules in a module stack 3 plus a termin...

Страница 20: ...verage 90 Dew formation Possible Applicable norms EN 61010 1 UL 61010 1 CAN CSA C22 2 61010 1 EN 61326 EMC requirements for electrical resources for con trol technology and laboratory use Resources fo...

Страница 21: ...Note If the valve is controlled via an external switch only one SENSORNET connection can be used due to the limited number of cable glands SEN SORNET connection 1 or 2 can be selected Valve switching...

Страница 22: ...ormative messages The MIQ CHV PLUS output module does not send any informative messages Information about Contents and structure of the log book and Structure of the message code can be found in the L...

Страница 23: ...SENSOR NET cable please specify required length in m when ordering SNCIQ SNCIQ UG 480 046 480 047 Sun shield for a unit of up to three stacked MIQ modules SSH IQ 109 295 Sun shield for a unit of up to...

Страница 24: ...Accessories and options MIQ CHV PLUS 24 ba75539d03 03 2018 All manuals and user guides at all guides com...

Страница 25: ...All manuals and user guides at all guides com...

Страница 26: ...ore than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of inn...

Отзывы: