 Position the power supply where it is easily accessible so that the meter can be separated from the power 

at any time. 
 
Check the power supply regularly. If the power supply is damaged it must be promptly replaced by an 
undamaged unit. 
 

 Use only the power supply VER05US050-JA (input 100-240 V~; 50/60 Hz; 0.18 A; output 5 V DC;  

1 A max.; class II)! 

 
 
 

Device description  

 

Measuring inputs 

3.1

 

Fig. 1  PTM40/PLF40 

 

1)  Sensor connection 
2)  USB port 
3)  Main Supply 

 

On the front of the meter, there are special connectors to connect the sensor and a USB interface cable. 
 

 Use only the sensors, sensor cables and interface cables recommended by the manufacturer. 

The notes and statements in the respective user manuals and data sheets apply to the use of the sensors and 
fittings. As the measuring system is intended for the measuring of analysis parameters you must keep in mind 
that the sensors must be calibrated and maintained regularly. 
 

 The measuring input must be free of potentials and must not be connected to power conducting potentials. 

All inputs must only be operated with the proper sensors. The direct connection of different signals is 
prohibited! 
 

 In order to protect the connections from the ingression of moisture and the resulting corrosion, 

you should always leave the sensor plugged into the meter. 
 

 Please note the switches when connecting to other devices (e.g. via USB interface). 

Internal connections in other devices (e.g. connecting GND to earth) can lead to impermissible voltage 
potentials that can impair the function of the meter itself or other devices or can even destroy them. 
 

 Use only interface cable (Interface HMG USB) to transfer data from the meter to the PC. This cable is not 

included in the delivery and must be purchased separately (

 chapter „Accessories”). 

 
You will find the software here: http://download.meinsberg.de/en/ 
 
 
 

 

Содержание PTM40

Страница 1: ...2018 03 14 Operating Manual PTM40 PLF40 pH ORP ISE conductivity meter...

Страница 2: ...User qualification 4 1 2 Specifications 4 1 3 Warning and safety information 5 1 4 2 Set up and Commissioning 6 Scope of delivery 6 2 1 Unpacking and Setup 6 2 2 Power supply 6 2 3 3 Device descriptio...

Страница 3: ...eturns 25 Notes about Instructions for Use These instructions for use are intended to show you the proper and safe handling of the product For the highest possible safety you must adhere to the listed...

Страница 4: ...ntion and handling of chemicals are adhered to Please observe the general see chapter 1 4 and all in the text additionally placed warnings and safety notes Specifications 1 3 Translation of the legall...

Страница 5: ...rature compensation cable offset TDS factor Temperature offset One point Automatic Warning and safety information 1 4 The meter PTM40 PLF40 has the protection class III It was manufactured and tested...

Страница 6: ...Use only the sensors sensor cables and interface cables recommended by the manufacturer The notes and statements in the respective user manuals and data sheets apply to the use of the sensors and fitt...

Страница 7: ...f analysis parameters you must keep in mind that the sensors must be calibrated and maintained regularly The measuring input must be free of potentials and must not be connected to power conducting po...

Страница 8: ...t Measuring mode Cursor right Change enter values Position value 1 Position value 1 Save confirm value Cursor left Measuring mode Cursor right The meter is turned on by pressing ON OFF Switching off t...

Страница 9: ...9 25 4 Temperature 5 Min main measured values 6 Max main measured values 7 Time 8 Date 9 Secondary measured value Menu structure 3 4...

Страница 10: ...ly in chapter 3 4 Under General the following device relevant basic settings can be configured Display backlight and contrast Password Password Clock Clock Reset Restart device Language Language Time...

Страница 11: ...e value Configuration of the switch off time 4 5 You can set the time on the meter after which the meter will be switched off automatically The data logger also records while the meter is off if the d...

Страница 12: ...ogs with the device switched on or off at the same time the power supply connected The correct setting of the real time clock is required for the proper function of the data logger During the reading...

Страница 13: ...clically output via the serial interface as ASCII characters Use only interface cable Interface HMG USB to transfer data from the meter to the PC This cable is not included in the delivery and must be...

Страница 14: ...accessories and the pH sensor EGA142 K010 U X This combination meets the requirements to determine the pH value electro chemical process as per EN ISO 10523 2012 The meter can be used wherever you wan...

Страница 15: ...he temperature of the measuring and calibration media must be measured or set up as a fixed temperature If the fixed temperature is activated it is used for temperature compensation The message FIX wi...

Страница 16: ...ich the settings should be changed Asymmetry Steepness An input dialog will allow you to change the respective calibration sensor values and their respective limits If these are not reached or exceede...

Страница 17: ...ompted to immerse the sensor into the third calibration medium Perform the same steps as with the first calibration solution 8 4 2 5 Automatic calibration Two and Three point The automatic calibration...

Страница 18: ...horoughly cleaned with distilled or deionized water prior to and between every measurement Immerse the sensor into the calibration solution and wait until a stable measured value is reached Ensure tha...

Страница 19: ...e submenu item for which the settings should be changed Asymmetry measured value 1 input value 1 An input dialog will allow you to change the respective calibration sensor values and their respective...

Страница 20: ...electro chemical process as per EN 27888 1993 When connected to the sensor the meter will capture the conductivity in S or mS the temperature as well as the salinity simultaneously All Meinsberg Cond...

Страница 21: ...ally selects the suitable measuring range TDS 5 shows the TDS value as a secondary variable Resist 5 shows the resistance value as a secondary variable 1 Measuring range switching possible 2 Measuring...

Страница 22: ...ompensation with adjustable temperature coefficient nLF non linear temperature compensation for natural waters as per DIN EN 27888 out For measurements without temperature compensation the temperature...

Страница 23: ...will be displayed Incorrect entry or Calibration error You may have to repeat the calibration service the sensor or replace it wear part 10 Scope of delivery PTM40 Set Lab pH meter Power supply Tripod...

Страница 24: ...roper handling use or illegitimate opening of the device results in loss of the guarantee rights The guarantee does not cover wear parts The breach of glass parts is also excluded To ascertain the gua...

Страница 25: ...GmbH Dr Karl Slevogt Stra e 1 D 82362 Weilheim Germany Service and Returns Xylem Analytics Germany Sales GmbH Co KG Sensortechnik Meinsberg Meinsberg Kurt Schwabe Stra e 6 D 04736 Waldheim Germany Te...

Отзывы: