9.5 Vibration measurement
Feature
Description
Frequency range
5 Hz to 1,100 Hz
Measurement method
Independent 3-axis
Primary output (per axis)
Single value RMS
Other outputs
Kurtosis and FFT
Vibration limit (max acceleration)
16 g
Threshold standard (Global)
ISO 10816-7
Threshold standard (North America)
ANSI/HI 9.6.4
9.6 Power
Feature
Description
Batteries (replaceable)
(2) 3.6 V AA, 2400 mAh, Lithium
Battery life
3
3 to 5 years
Default sampling rate
1 sample per 30 minutes
Available sampling rates (one sample per unit of
time)
10 seconds to 12 hours
9.7 Wireless communication
Feature
Description
Network type
Bluetooth
®
Low Energy 5.01
2.4 GHz ISM band
RF 3.29 mW (5.17 dBm)
Connection range (without interference)
30 meters (100 feet)
9.8 Physical properties
Feature
Description
Weight
145 g (0.32 lb)
Status
LED
Mounting method (standard)
Magnetic (16 mm potted magnets)
Mounting method (optional)
Drill and tap with plate
9.9 Part numbers
Part
Part number
optimyze (standard sensor)
P2007000
optimyze battery replacement kit
P2007030
optimyze optional flat plate mounting kit
P2007031
3
using default sampling rate at 25°C, one connection for each day
9 Technical Specification
22
optimyze
™
Installation, Operation, and Maintenance Manual
Содержание optimyze
Страница 1: ...Installation Operation and Maintenance Manual P2007013_1 0 optimyze...
Страница 2: ......
Страница 30: ......
Страница 31: ......