2b: We deliver two types of sensor brackets that can be used
in almost any installation. The bracket shown is a flume
mounting bracket (order no. 200230 / 200235).
3: The ultrasonic sensor should be installed so that
the bottom of the sensor is
as close as possible
to
the max. height of the head but
not closer than the
blocking distance.
Measuring range:
0 - 1’
0 - 3’
Blocking distance: )*
16”
16”
Min. measuring range:
4”
12”
Max. measuring range:
12”
36”
Max. sensor height
➁
: 30"
54"
)* 14” for System Package 2.
(w. Shuttle
®
Level Transmitter as signal amplifier.)
Maximum sensor height
➁
= Blocking distance
➀
+ measuring range
➃
➀
Blocking distance
➁
Sensor height
➂
Actual measurement
➃
Measuring range
➀
➁
➂
➃