en
– Original instructions
18
3.5 Motor technical data
Table 1: Electrical, Environmetal and Installation specifications
e-SM Drive model
103
105
107
111
115
303
305
307
311
315
322
Input
Input frequency [Hz]
50/60 ± 2
Mains supply
LN
L1 L2 L3
Nominal input voltage [V]
208÷240 ±10%
208÷240 / 380÷460 ±10%
380÷
460
±10%
Max. Input Current Continuous
[A]
2,3
3,3
4,4
6,3
8,6
-
-
-
-
-
-
PDS Efficiency Class
IES2
Output
Min÷Max Speed [rpm]
800÷3600
Leakage Current [mA]
< 3,5
I/O au 15VDC power
supply [mA]
Imax < 40
Fault signal relay
1 x NO Vmax < 250 [VAC] , Imax < 2 [A]
2 x NO Vmax < 250 [VAC] , Imax < 2 [A]
EMC (Electro Magnetic
Compatibility)
See par.1.8 DECLARATION OF CONFORMITY
.
Installations must be done according to EMC good practice guidelines
(e.g. avoiding pigtails on drive side)
Sound Pressure LpA [dB(A)]
< 62 @3000 [rpm]
<66 @3600 [rpm]
Insulation class
Class 155 F
Enclosure Rate
IP 55, Enclosure Type 1
Protect the product from direct sunlight and rainfall
Relative humidity (storage &
operating)
5% ÷ 95% RH
Storage temperature [°C] /[°F]
-25÷65 / -13÷149
Operating temperature
[°C] /[°F]
-20÷50 / -4÷122
Air Pollution
Pollution Degree 2
Altitude
Max. 1000 [m] /3280 [feet] above sea level. For installation over 1000 [m] above
sea level de-rating may occur
Содержание LOWARA e-SVE
Страница 4: ...en Original instructions 4...