background image

3

WARNING!

It is the installer’s responsibility to use 
hoses with suitable properties. The use 
of hose that is not suitable could cause 
damage to the pump, operator or the 
surrounding environment. Loose hose 
connections can cause environmental 
and safety issues, check all connections 
after initial installation and on a daily 
basis thereafter. Tighten if required. It is 
recommended the hose is installed prior 
to installing electrical supply.

•  Pipe runs should be kept as straight as 

possible, avoiding rising and dipping over 
obstructions, shown below.

•  In order to ensure good priming always keep 

connections tight. 

•  All seals should be checked regularly and 

changed if leaking, as leakage could be 
dangerous.

•  The pump should be installed so that the mo-

tor is protected from moisture and bilge water.

•  The pump should not be run with a closed 

outlet.

• 

Pump is rated to IP55 Ingress Protection.

•  Install the Ballast SuperKing pump in accor-

dance to ISO 10133.

•  If installed in a vertical position, the motor 

must be above the pump head, shown below.  
This will prevent liquid from dripping onto the 
motor if there is a seal leak.

Pump Unit Information:

•  33610-0107 − 1-1/4” Hose Barb, 12Vdc.

Intermittent duty cycles of 5 minutes ON and 
10 minutes OFF.

Pump Application

•  The pump has been designed to transfer 

freshwater and seawater into ballast tanks.

•  The pump is reversible, therefore freshwater 

or seawater can be transferred from source to 
ballast and returned from ballast to source.

•  To reduce ballast, the pump will reverse to 

pump ballast back over board.

•  The same operation is used for ballast transfer 

between two tanks.

INSTALLATION

PUMP SET-UP

•  Verify that all components are present.

•  Check the pump unit has not been damaged 

during transit.

•  Ensure inlet and outlet ports are free from dirt, 

dust or packaging material.

•  Ensure electrical data corresponds to those 

indicated on the product label and ensure 
the correct fuse is fitted in the power line (see 
Technical Specifications for recommended 
fuse).

•  Fit a strainer on the inlet hose to prevent larg-

er debris from entering the pump, ensure this 
is clean and free from dirt before use.

•  Before connecting the inlet and outlet hoses, 

ensure they are free from dirt. 

•  Secure 1-1/4” (32 mm) ID hose either directly 

to the ports, using stainless steel hose clamps.

•  Use spiral reinforced hose (with a smooth 

internal bore) that will not collapse under suc-
tion, or rigid or semi-rigid pipework systems.

•  The pump should be mounted on any flat 

suitable surface.

•  Fit the pump in a dry, well ventilated position 

where there is full access for service.

•  Use rubber grommets provided to minimize 

the vibration, do not over tighten the mount-
ing screws.

•  All marine pumps discharging overboard must 

be installed with the overboard discharge well 
above both static and heeled waterlines.

Install overboard discharge well above both 

static and heeled waterlines.

Содержание JABSCO Ballast SuperKing

Страница 1: ...Ballast SuperKing DC Flexible Impeller Pump ...

Страница 2: ...e equipment If the recommended safety notices are not strictly observed it can lead to serious or fatal injuries of personnel and or material damage It is not recommended to run SuperKing pump dry Do not run the pump with a closed or restricted discharge line This pump is not a submersible pump Failure to observe the recommended safety procedures can lead to material damage Only qualified Service ...

Страница 3: ...he pump is reversible therefore freshwater or seawater can be transferred from source to ballast and returned from ballast to source To reduce ballast the pump will reverse to pump ballast back over board The same operation is used for ballast transfer between two tanks INSTALLATION PUMP SET UP Verify that all components are present Check the pump unit has not been damaged during transit Ensure in...

Страница 4: ... body to motor screws 21 28 lbf ins 2 4 3 1 Nm ELECTRICAL CONFIGURATION AND INSTALLATION 33710 0107 configured with Deutsch DTP04 2P connector Pin 1 Positive Pin 2 Negative It is the responsibility of the installer to per form the correct installation Make all electrical connections in dry loca tions connections in humid environments should be sealed to prevent corrosion Protect the circuit with a...

Страница 5: ...ensional Drawings inches mm 5 12 130 3 56 90 4 2 56 65 89 22 5 2 80 71 1 8 98 228 1 18 30 3 58 91 1 99 50 6 1 36 34 45 2 PLCS 1 25 31 75 2 PLCS 3 74 95 64 16 3 Deutsch DTP04 2P Pin 1 Positive Pin 2 Negative ...

Страница 6: ...t to ensure self priming The pump can run dry up to 1 minute after running wet for 5 minutes TECHNICAL SPECIFICATIONS The data specified in the above table refers to performance running at the ideal efficiency points on water at 68 F 20 C with battery charged at 12 0Vdc For longer installations fit thicker cables reference ISO 10133 The wire length is the total distance from the battery to the pum...

Страница 7: ...tors and cables are in good condition once a month 1 7 2 5 6 3 4 KITS AND ACCESSORIES 33610 0107 Key Part Number Description Qty 1 9328 0202 Kit End Cover 1 2 End Cover O ring 1 3 91004 0090 Kit Screw 12 24 x 375 SL FIL BR 3 per 3 4 98019 0020 Kit Screw 10 32 x 1 2 SL HX BR 3 per 2 5 6303 0007 P Kit Impeller 1 per 2 6 18753 0384 Kit Lip Seal 1 per 1 7 50070 0040 Impeller Removal Tool 1 6303 0007 P...

Страница 8: ...CLUDED EXCEPT AS OTHERWISE PROVIDED BY LAW BUYER S EXCLUSIVE REMEDY AND SELLER S AGGREGATE LIABILITY FOR BREACH OFANYOFTHE FOREGOINGWARRANTIESARE LIMITEDTO REPAIRING OR REPLACINGTHE PRODUCTAND SHALLINALLCASES BE LIMITEDTOTHEAMOUNTPAID BYTHE BUYER HEREUNDER IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES WHETHER DIRECT INDIRECT LIQUIDATED INCIDENTAL CONSEQUENTIAL PUNITIVE EXEMPLARYOR SPE...

Отзывы: